SearcharxivSearch

arXiv · 2112.05232

Performance of the new Readout Electronics for the ATLAS (s)MDT Chambers and Future Colliders at High Background Rates

Abstract

Small-diameter Drift Tube (sMDT) detectors with 15 mm tube diameter have proven to be excellent candidates for precision muon tracking detectors in experiments at future hadron colliders like HL-LHC and FCC-hh where unprecedentedly high background rate capabilities are required. sMDT chambers are currently being installed in the inner barrel layer of the ATLAS muon spectrometer. The rate capability of the sMDT drift tubes in terms of muon detection efficiency and spatial resolution is limited by the performance of the readout electronics. A new (s)MDT ASD (Amplifier-Shaper-Discriminator) readout chip for use at the HL-LHC and future hadron colliders with a faster peaking time compared to the old chip has been developed, reducing the discriminator threshold crossing time jitter and thus improving the time- and spatial resolution with and without $\gamma$-background radiation. Additionally, a method compensating the gas gain drop due to space charge at high $\gamma$-background hit flux by adjusting the sMDT operating voltage will be presented. Simulations show, that the addition of active baseline restoration circuits in the front-end electronics chips in order to suppress signal-pile-up effects at high counting rates further leads to significant improvement of both efficiency and resolution. Extensive tests using sMDT test chambers have been performed at the CERN Gamma Irradiation Facility (GIF++). Chambers equipped with new readout chips with improved pulse shaping and discrete readout circuits with baseline restoring functionality have been tested.

Explore related subjects

Keep this discovery

BibTeXRIS

G. H. Eberwein, O. Kortner, H. Kroha, E. Voevodina. 2021-12-09. Performance of the new Readout Electronics for the ATLAS (s)MDT Chambers and Future Colliders at High Background Rates. https://arxiv.org/abs/2112.05232

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det