SearcharxivSearch

arXiv · 2203.00688

High-resolution absorption measurements with free-electron lasers using ghost spectroscopy

Abstract

We demonstrate a simple and robust high-resolution ghost spectroscopy approach for x-ray and extreme ultraviolet absorption spectroscopy at free-electron laser sources. Our approach requires an on-line spectrometer before the sample and a downstream bucket detector. We use this method to measure the absorption spectrum of silicon, silicon carbide and silicon nitride membranes in the vicinity of the silicon L2,3-edge. We show that ghost spectroscopy allows the high-resolution reconstruction of the sample spectral response using a coarse energy scan with self-amplified spontaneous emission radiation. For the conditions of our experiment the energy resolution of the ghost-spectroscopy reconstruction is higher than the energy resolution reached by scanning the energy range by narrow spectral bandwidth radiation produced by the seeded free-electron laser. When we set the photon energy resolution of the ghost spectroscopy to be equal to the resolution of the measurement with the seeded radiation, the measurement time with the ghost spectroscopy method is shorter than scanning the photon energy with seeded radiation. The exact conditions for which ghost spectroscopy can provide higher resolution at shorter times than measurement with narrow band scans depend on the details of the measurements and on the properties of the samples and should be addressed in future studies.

Explore related subjects

Keep this discovery

BibTeXRIS

Yishai Klein, Edward Strizhevsky, Flavio Capotondi, Dario De Angelis, Luca Giannessi, Matteo Pancaldi, Emanuele Pedersoli, Giuseppe Penco, Kevin C. Prince, Or Sefi, Young Yong Kim, Ivan A. Vartanyants, Sharon Shwartz. 2022-03-01. High-resolution absorption measurements with free-electron lasers using ghost spectroscopy. https://doi.org/10.1103/physreva.107.053503

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det