arXiv · 2203.03126
Measurements of Rayleigh Ratios in Linear Alkylbenzene
Abstract
In present work an experiment has been designed to measure the Rayleigh ratio directly at $405$ nm and $432$ nm for linear alkylbenzene which is a common solvent used in liquid scintillator detectors of neutrino experiments. The perpendicularly polarized Rayleigh ratio is determined to be $(4.52\pm 0.28)\times 10^{-6}$ m$^{-1}\cdot$ sr$^{-1}$ at $405$ nm and $(3.82\pm 0.24)\times 10^{-6}$ m$^{-1}\cdot$ sr$^{-1}$ at $432$ nm, and the corresponding Rayleigh scattering length is $L_{Ray} = 22.9\pm 0.3(\mathrm{stat.})\pm 1.7(\mathrm{sys.})$ m at $405$ nm and $L_{Ray}= 27.0\pm 0.9(\mathrm{stat.})\pm 1.8(\mathrm{sys.})$ m at $432$ nm.
Explore related subjects
Keep this discovery
Miao Yu, Wenjie Wu, Na Peng, Taozhe Yu, Yayun Ding, Qian Liu, Feng Ren, Zhenyu Zhang, Xiang Zhou. 2022-03-07. Measurements of Rayleigh Ratios in Linear Alkylbenzene. https://doi.org/10.1063/5.0091847
Cite the original work for its findings. Save a collection to share your selection of sources.