SearcharxivSearch

arXiv · 2207.04283

Development of a new high-speed data acquisition system prototype for SOI pixel detector using SiTCP-XG, a 10-gigabit Ethernet network processor

Abstract

We are developing a new readout board with a newer generation field-programmable gate array (FPGA) and the 10-gigabit ethernet to improve the performance and usability of the current readout board based on the 1-gigabit Ethernet. In this new readout board, the SiTCP-XG network processor supporting 10-gigabit Ethernet was implemented. SiTCP is a network processor circuit running on FPGA, and SiTCP-XG is the newly developed version of the SiTCP that supports 10-gigabit Ethernet. Before developing the new board, we constructed a prototype system using the Xilinx FPGA evaluation board KC705 to evaluate the SiTCP-XG. This prototype system was tested with the SOI pixel detector, which has 425,984 (column 832 x row 512 matrix) pixels and a pixel size of 17 x 17 um at the synchrotron beamlines of the PhotonFactory (KEK). This was the first test of the X-ray imaging for this system. The results showed that this system worked stably with a transfer rate of 682 Mbps (equivalent to a frame rate of 100 fps, limited by detector operation parameters), and also worked stably with a transfer rate of 2.4 Gbps (equivalent to 350 fps, the maximum rate limited by the detector performance). These results suggest that the SiTCP-XG system has sufficient transfer performance to cover the SOIPIX detector performance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ryutaro Nishimura, Shunji Kishimoto, Yasuo Arai, Toshinobu Miyoshi. 2022-07-09. Development of a new high-speed data acquisition system prototype for SOI pixel detector using SiTCP-XG, a 10-gigabit Ethernet network processor. https://doi.org/10.1088/1742-6596%2F2374%2F1%2F012093

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det