SearcharxivSearch

arXiv · 2208.09971

Gas electron tracking detector for beta decay experiments

Abstract

For identification and 3D-tracking of low-energy electrons a new type of gas-based detector was designed that minimizes scattering and energy loss. The current version of the detector is a combination of a plastic scintillator, serving as a trigger source and energy detector, and a hexagonally structured multi-wire drift chamber (MWDC), filled with a mixture of helium and isobutane gas. The drift time information is used to track particles in the plane perpendicular to the wires, while a charge division technique provides spatial information along the wires. The gas tracker was successfully used in the miniBETA project as a beta spectrometer for a measurement of the weak magnetism form factor in nuclear beta decay. The precision of the three-dimensional electron tracking, in combination with low-mass, low-Z materials and identification of backscattering from scintillator, facilitated a reduction of the main systematics effects. At certain conditions, a spatial resolution better than 0.5 mm was obtained in the plane perpendicular to the wires, while resolutions of about 6 mm were achieved along wires. Thanks to precise tracking information, it is possible to eliminate electrons and other particles not originating from the desired decay with high efficiency. Additionally, using the coincidence between MWDC and scintillator, background from gamma emission typically accompanying radioactive decays, was highly suppressed. An overview of different event topologies is presented together with the tracker's ability to correctly recognize them. The analysis is supported by Monte Carlo simulations using Geant4 and Garfield++ packages. Finally, the preliminary results from the 114In spectrum study are presented.

Explore related subjects

Keep this discovery

BibTeXRIS

D. Rozpedzik, L. De Keukeleere, K. Bodek, L. Hayen, K. Lojek, M. Perkowski, N. Severijns. 2022-08-21. Gas electron tracking detector for beta decay experiments. https://doi.org/10.1088/1748-0221%2F17%2F09%2Fc09005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det