SearcharxivSearch

arXiv · 2210.10576

Coincidence-based reconstruction for reactor antineutrino detection in gadolinium-doped Cherenkov detectors

Abstract

A reconstruction algorithm has been developed to capitalize on advances in Cherenkov technology for reactor antineutrino detection. Large gadolinium-doped water (Gd-H$_2$O) Cherenkov detectors are a developing technology which use Gd loading to increase the visibility of the neutrons produced in inverse beta decay (IBD) interactions, which produce positron-neutron pairs coincident in time and space. In this paper, we describe the reconstruction which uses the combined light from both events in an IBD pair to accurately reconstruct the interaction vertex. The algorithm has been applied to the reconstruction of reactor antineutrinos in Gd-H$_2$O and in Gd-doped water-based liquid scintillator (Gd-WbLS), an advanced detector medium which is also currently in development. Compared to a single-event reconstruction, the combined reconstruction improves vertex resolution for reactor IBD positrons by up to a factor of 4.5 at the lowest energies. IBD-neutron vertex resolution was found to improve by more than 30% in most instances. Powerful background rejection with the coincidence reconstruction can be achieved by requiring a minimum quality of fit. This was found to reject up to 94% of accidental coincidences of uncorrelated background events, while retaining at least 97.5% of the IBD signal pairs.

Explore related subjects

Keep this discovery

BibTeXRIS

Liz Kneale, Michael Smy, Matthew Malek. 2022-10-19. Coincidence-based reconstruction for reactor antineutrino detection in gadolinium-doped Cherenkov detectors. https://doi.org/10.1016/j.nima.2023.168375

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det