SearcharxivSearch

arXiv · 2212.10896

Development and operation of the CGEM Inner Tracker for the BESIII experiment

Abstract

The extension of data acquisition for the BEijing Spectrometer (BESIII) experiment until at least 2030 has resulted in upgrades to both the accelerator and the detector. An innovative Cylindrical Gas Electron Multiplier (CGEM) is under construction to upgrade the inner tracker, which is suffering from aging. The CGEM Inner Tracker (CGEM -IT) was designed to restore efficiency and enhance the reconstruction of the secondary vertexes position. Reconstruction in the magnetic field of 1 T requires an analog readout and an electronic contribution to the time resolution better than 5 ns. The entire system consists of about 10,000 electronic channels and must maintain a peak rate of 14 kHz/strip of signal hits for the innermost layer of the CGEM-IT. The CGEM readout system is based on the innovative TIGER ASIC, which is manufactured using 110 nm CMOS technology. A special readout chain consisting of GEM Read Out Cards (GEMROC) was developed for data acquisition. Two of three layers, equipped with the final electronics, have been operating in Beijing since January 2020 collecting cosmic ray data in a test facility, remotely controlled by the Italian group due to the pandemic situation. Since it was not possible to perform further tests on the cylindrical detector, in July 2021, a test beam was conducted at CERN with the final electronics configuration on a small prototype consisting of four triple-GEM planar detectors. In this presentation, the general status of the project CGEM-IT will be presented, with particular emphasis on the results of the test beam data collection.

Explore related subjects

Keep this discovery

BibTeXRIS

Alberto Bortone. 2022-12-21. Development and operation of the CGEM Inner Tracker for the BESIII experiment. https://doi.org/10.1016/j.nima.2022.167957

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.