arXiv · 2301.04499
Precision measurement of an electron pump at 2 GHz
Abstract
A well-characterised sample of silicon tunable-barrier electron pump has been operated at a frequency of 2 GHz using a custom drive waveform, generating a pump current of 320 pA. Precision measurements of the current were made as a function of pump control parameters, using a blind protocol, over a 7-week campaign. The combined standard uncertainty for each 10 hour measurement was 0.1 parts per million. The pump current exhibits a plateau along the exit gate voltage flat to approximately 0.1 parts per million, but offset from ef by 0.2 parts per million. This offset may be a sign of errors in the current traceability chain, indicating a limit to the accuracy of small current scaling using existing methods based on cryogenic current comparators.
Explore related subjects
Keep this discovery
Stephen Giblin, Gento Yamahata, Akira Fujiwara, Masaya Kataoka. 2023-01-11. Precision measurement of an electron pump at 2 GHz. https://doi.org/10.1088/1681-7575/ace054
Cite the original work for its findings. Save a collection to share your selection of sources.