SearcharxivSearch

arXiv · 2301.10495

An LHCb Vertex Locator (VELO) for 2030s

Abstract

The Upgrade II of the LHCb detector, foreseen for 2031, will operate at an instantaneous luminosity of 1.5 x 10$^{34}$ cm$^{-2}$s$^{-1}$, accumulating a sample of more than 300 fb$^{-1}$. To cope with the estimated pile-up of 42 and 200 charged particle tracks per event, precise timing will be added to the tracking and vertexing sub-systems. A new Vertex Locator (VELO), capable to manage the expected 7.5-fold increase in data rate, occupancy, and radiation fluence is needed. Based on a 4D hybrid silicon pixel technology, with enhanced rate and timing capabilities on the ASIC, the new VELO will allow for precise beauty & charm hadron identification and real time pattern recognition. Through detailed simulations, the fluence, inner radius, material budget and pixel size phase space are explored, while constraining the Impact Parameter (IP) resolution to the Upgrade I value. Two distinct scenarios emerge as starting points for further optimizations, with inner radii and end of life fluence of 5.1 mm at 6 x 10$^{16}$ n$_{eq}$/cm$^{2}$ and 12.5 mm at 8 x 10$^{15}$ n$_{eq}$/cm$^{2}$ respectively. Advances and current R&D on sensor technologies, including LGADs, 3Ds and planar pixels are reviewed, focusing on radiation hard designs and defect engineering. ASIC related requirements with respect to sensor capacitance and power budget are taken into consideration for achieving the 30 ps per hit timing target towards the future 28 nm protype submission. Improvements in cooling, mechanics and vacuum implementations are examined with respect to each layout scenario. The use of bi-phasic Krypton cooling is evaluated as an option for the case of above 1.5 W/cm$^{2}$ power dissipation. Replaceable sensor modules, coupled with 3D printed titanium supports are also under consideration. Finally, a comprehensive R&D schedule towards final design optimization within a six-year period is discussed.

Explore related subjects

Keep this discovery

BibTeXRIS

Evangelos Leonidas Gkougkousis. 2023-01-25. An LHCb Vertex Locator (VELO) for 2030s. https://arxiv.org/abs/2301.10495

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det