3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers

Abstract

X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.

Explore related subjects

Keep this discovery

BibTeXRIS

Patrick E. Konold, Tong You, Johan Bielecki, Joana Valerio, Marco Kloos, Daniel Westphal, Alfredo Bellisario, Tej Varma, August Wolter, Jayanath C. P. Koliyadu, Faisal H. M. Koua, Romain Letrun, Adam Round, Tokushi Sato, Petra Mésźaros, Leonardo Monrroy, Jennifer Mutisya, Szabolcs Bódizs, Taru Larkiala, Amke Nimmrich, Roberto Alvarez, Richard Bean, Tomas Ekeberg, Richard A. Kirian, Sebastian Westenhoff, Filipe R. N. C. Maia. 2023-06-13. 3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers. https://doi.org/10.1107/s2052252523007972

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det