SearcharxivSearch

arXiv subjects

Tokushi Sato

Publications and source records attributed to Tokushi Sato.

At least 19 recordsLinked to original sources

Train-Resolved Statistical Recovery of Weak SAXS Signals in Liquids at the European XFEL

We present a train-resolved SAXS methodology for recovering weak scattering signals from high-repetition-rate XFEL datasets and apply it to aqueous L-cysteine solutions measured at the European XFEL. Independent scale-plus-offset fitting was performed for matched cysteine and water train pairs, followed by subtraction of transmission-matched water--water controls. The 0.5 M dataset reveals a reproducible sign-changing residual SAXS signal that increases with incident XFEL transmission and remains after removal of detector-wide scaling, additive offsets, and matched water--water control residuals. Convergence and block-averaging analyses show that the residual emerges progressively as independent train pairs are accumulated and exhibits uncertainty scaling close to the expected inverse square-root dependence on N. These results establish a statistically robust transmission-dependent residual SAXS contribution whose microscopic origin remains unresolved, while demonstrating that train-resolved observables combined with matched controls can substantially improve sensitivity to weak scattering signals in high-repetition-rate XFEL experiments.

physics.optics

Time Resolved Study of Laser Induced Ultrafast Alloying Processes in Au/Pd Core Shell Nanorods

Femtosecond laser-induced alloying presents a novel approach to modifying bimetallic systems. Visualizing ultrafast processes during laser-induced alloying is essential to uncover fundamental mechanisms associated with phase transformations, which enables precise control over material composition and structure at the atomic level. In this study, we investigated the ultrafast dynamics of laser-induced alloying of Au/Pd core-shell nanorods using a time-resolved X-ray diffraction technique at an X-ray free-electron laser facility, capturing the structural evolution from picoseconds to microsecond timescales. We found that a laser fluence threshold of ~ 48 mJ/cm2 with 800 nm excitation is sufficient for melting and subsequent alloy formation. Above this threshold, the formation of Au1.51Pd0.49 was observed, and we found that alloying is not a single-step phenomenon; instead, it is a dynamic process involving interdiffusion.

cond-mat.mtrl-sci

Single-particle incoherent diffractive imaging and amplified spontaneous emission in copper nanocubes

We demonstrate element-specific incoherent diffractive imaging (IDI) of single copper nanocubes using intensity correlations of K$\alpha$ fluorescence at a hard X-ray free-electron laser. Combining single particle diffraction classification with IDI, we retrieve the form factor of 88 nm cubes with 20 nm resolution, extending IDI to the destructive single-particle regime with a large gain in resolution. IDI visibility drops sharply above a fluence of $10^2$ J/cm$^2$, consistent with the assumption of amplified spontaneous emission. Our results reveal fundamental limits for high-fluence nanoimaging towards future single-particle X-ray imaging.

physics.optics

Nonlinear phenomena in X-ray fluorescence from single nanoparticles under extreme conditions

Materials exposed to intense femtosecond X-ray pulses with energies above their K-shell absorption edge can enter an extremely ionized state, which could give rise to nonlinear phenomena, such as saturable absorption and reverse saturable absorption. In this work, we investigate these effects on single copper nanoparticles irradiated by an X-ray free-electron laser pulse. We study the properties of the K$\alpha$ fluorescence for two different short pulse durations and three X-ray incident energies below and above the K-shell absorption edge, and correlate these with incident fluence estimates based on coherent diffraction. We observe that the incident fluence of the pulse and not its duration, is the main factor that modulates the nonlinear response, which leads to an effective shortening of the fluorescence emission. Our findings have implications for fluorescence-based methods for imaging single particles using transiently coherent fluorescence, or diffractive imaging through transient resonances.

physics.optics

Direct observation of the exciton polaron by serial femtosecond crystallography on single CsPbBr$_3$ quantum dots

The outstanding opto-electronic properties of lead halide perovskites have been related to the formation of polarons. Nevertheless, the observation of the atomistic deformation brought about by one electron-hole pair in these materials has remained elusive. Here, we measure the diffraction patterns of single CsPbBr$_3$ quantum dots (QDs) with and without resonant excitation in the single exciton limit using serial femtosecond crystallography (SFX). By reconstructing the 3D differential diffraction pattern, we observe small shifts of the Bragg peaks indicative of a crystal-wide deformation field. Building on DFT calculations, we show that these shifts are consistent with the lattice distortion induced by a delocalized electron and a localized hole, forming a mixed large/small exciton polaron. This result creates a clear picture of the polaronic deformation in CsPbBr$_3$ QDs, highlights the exceptional sensitivity of SFX to lattice distortions in few-nanometer crystallites, and establishes an experimental platform for future studies of electron-lattice interactions.

cond-mat.mtrl-sci

Observation of Aerosolization-induced Morphological Changes in Viral Capsids

Single-stranded RNA viruses co-assemble their capsid with the genome and variations in capsid structures can have significant functional relevance. In particular, viruses need to respond to a dehydrating environment to prevent genomic degradation and remain active upon rehydration. Theoretical work has predicted low-energy buckling transitions in icosahedral capsids which could protect the virus from further dehydration. However, there has been no direct experimental evidence, nor molecular mechanism, for such behaviour. Here we observe this transition using X-ray single particle imaging of MS2 bacteriophages after aerosolization. Using a combination of machine learning tools, we classify hundreds of thousands of single particle diffraction patterns to learn the structural landscape of the capsid morphology as a function of time spent in the aerosol phase. We found a previously unreported compact conformation as well as intermediate structures which suggest an incoherent buckling transition which does not preserve icosahedral symmetry. Finally, we propose a mechanism of this buckling, where a single 19-residue loop is destabilised, leading to the large observed morphology change. Our results provide experimental evidence for a mechanism by which viral capsids protect themselves from dehydration. In the process, these findings also demonstrate the power of single particle X-ray imaging and machine learning methods in studying biomolecular structural dynamics.

q-bio.BM

Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources

X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.

physics.ins-det

Resolving non-equilibrium shape variations amongst millions of gold nanoparticles

Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential, three challenges have to be overcome: (1) simultaneous parametrization of structural variability in real and reciprocal spaces; (2) efficiently inferring the latent parameters of each SPI measurement; (3) scaling up comparisons between $10^5$ structural models and $10^6$ XFEL-SPI measurements. Here, we describe how we overcame these three challenges to resolve the non-equilibrium shape distributions within millions of gold nanoparticles imaged at the European XFEL. These shape distributions allowed us to quantify the degree of asymmetry in these particles, discover a relatively stable `shape envelope' amongst nanoparticles, discern finite-size effects related to shape-controlling surfactants, and extrapolate nanoparticles' shapes to their idealized thermodynamic limit. Ultimately, these demonstrations show that XFEL SPI can help transform nanoparticle shape characterization from anecdotally interesting to statistically meaningful.

cond-mat.mes-hall

3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers

X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.

physics.ins-det

Megahertz X-ray Multi-projection imaging

X-ray time-resolved tomography is one of the most popular X-ray techniques to probe dynamics in three dimensions (3D). Recent developments in time-resolved tomography opened the possibility of recording kilohertz-rate 3D movies. However, tomography requires rotating the sample with respect to the X-ray beam, which prevents characterization of faster structural dynamics. Here, we present megahertz (MHz) X-ray multi-projection imaging (MHz-XMPI), a technique capable of recording volumetric information at MHz rates and micrometer resolution without scanning the sample. We achieved this by harnessing the unique megahertz pulse structure and intensity of the European X-ray Free-electron Laser with a combination of novel detection and reconstruction approaches that do not require sample rotations. Our approach enables generating multiple X-ray probes that simultaneously record several angular projections for each pulse in the megahertz pulse burst. We provide a proof-of-concept demonstration of the MHz-XMPI technique's capability to probe 4D (3D+time) information on stochastic phenomena and non-reproducible processes three orders of magnitude faster than state-of-the-art time-resolved X-ray tomography, by generating 3D movies of binary droplet collisions. We anticipate that MHz-XMPI will enable in-situ and operando studies that were impossible before, either due to the lack of temporal resolution or because the systems were opaque (such as for MHz imaging based on optical microscopy).

eess.IV

Ultrasound cavitation and exfoliation dynamics of 2D materials re-vealed in operando by X-ray free electron laser megahertz imaging

Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simultaneously, most theories reported to date still remain elusive. Here, using the ultra-short X-ray Free Electron Laser pulses (~25ps) with a unique pulse train structure, we applied MHz X-ray Microscopy and machine-learning technique to reveal unambiguously the full cycles of the ultrasound cavitation and graphite layer exfoliation dynamics with sub-microsecond and micrometer resolution. Cyclic fatigue shock wave impacts produced by ultrasound cloud implosion were identified as the dominant mechanism to deflect and exfoliate graphite layers mechanically. For the graphite flakes, exfoliation rate as high as ~5 angstroms per shock wave impact was observed. For the HOPG graphite, the highest exfoliation rate was ~0.15 angstroms per impact. These new findings are scientifically and technologically important for developing industrial upscaling strategies for ultrasonic exfoliation of 2D materials.

cond-mat.mtrl-sci

Online dynamic flat-field correction for MHz Microscopy data at European XFEL

The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as phase retrieval and modal decomposition. In addition, access to normalized projections during data acquisition can play an important role in decision-making and improve the quality of the data. However, the stochastic nature of XFEL sources hinders the use of existing flat-flied normalization methods during MHz X-ray microscopy experiments. Here, we present an online dynamic flat-field correction method based on principal component analysis of dynamically evolving flat-field images. The method is used for the normalization of individual X-ray projections and has been implemented as an online analysis tool at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of EuXFEL.

physics.ins-det

Absolute spectral metrology of XFEL pulses using diffraction in crystals

At modern X-ray sources, such as synchrotrons and X-ray Free-Electron Lasers (XFELs), it is important to measure the absolute value of the photon energy directly. Here, a method for absolute spectral metrology is presented. A photon energy estimation method based on the spectral measurements and rocking of diffracting crystals is presented. The photon energy of SASE1 channel of the European XFEL was measured, and the benefits and applications of the precise photon energy evaluation are discussed.

physics.ins-det

Metastable structure of photoexcited WO$_{3}$ determined by the pump--probe extended X-ray absorption fine structure spectroscopy and constrained thorough search analysis

We have determined the local structure of photoexcited metastable WO$_3$ created 150 ps after 400 nm laser irradiation by the pulse pump--probe L$_3$-edge extended X-ray absorption fine structure spectroscopy and the constrained thorough search analysis. We have found a highly distorted octahedral local structure with one of the shortest W=O bonds being further shortened to 1.66 Åwhile the other five bonds were elongated even though theoretical calculations predicted the reverse change. We discuss this contradiction and propose a possible structure for the metastable state.

cond-mat.mtrl-sci

Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging

One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.

eess.IV

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 $μ$J. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

physics.optics

3D diffractive imaging of nanoparticle ensembles using an X-ray laser

We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.

physics.app-ph

Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources

We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.

physics.ins-det