SearcharxivSearch

arXiv · 2307.02708

Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs

Abstract

We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs. We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions. In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems. TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.

Explore related subjects

Keep this discovery

BibTeXRIS

Kepler Domurat-Sousa, Cameron Poe, Henry J. Frisch, Bernhard W. Adams, Camden Ertley, Neal Sullivan. 2023-07-06. Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs. https://doi.org/10.1016/j.nima.2023.168676

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph