SearcharxivSearch

arXiv · 2311.17222

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

Abstract

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but large in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to deficiencies in the bias wiring or microwave multiplexing circuit. We use a method based on group triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/$\Delta$E $\sim$ 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can consider mitigations.

Explore related subjects

Keep this discovery

BibTeXRIS

Panthita Triamkitsawat, Tejas Guruswamy, Orlando Quaranta, Lisa Gades, Umeshkumar Patel, Antonino Miceli. 2023-11-28. Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array. https://doi.org/10.1007/s10909-024-03109-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det