SearcharxivSearch

arXiv · 2312.14365

An ab-initio derivation to discuss the heterodyne versus direct detection decision problem for astronomical infrared interferometry

Abstract

A consistent and explicit spectral comparison between heterodyne (HD) and direct detection (DD) derived from first principles including the atmospheric transmission and low beam-filling factors could not be found yet in literature but is needed for decisions in technology planification for future infrared interferometry facilities which are e.g. focused on planet formation. This task requires both, high sensitivity continuum and Doppler-resolved emission and absorption line detection in the mid-IR range (N- and Q-bands) at lower source temperatures (300-1000 K). The signal-to-noise ratios (SNRs) are derived for both schemes within the same semi-classical theory, which consists of classical mode theory for coupling to an antenna and occupation of these modes by quanta of three radiation fields, the thermal signal, the thermal background, and for HD also the coherent local oscillator (LO). The effects of very small beam filling factors (interferometry) and atmospheric absorption/emission could be consistently incorporated this way, as well as quantum-noise propagation which allows in HD the consideration of balanced mixers with cross-correlation (CC). Especially, the transition from pre- to post-detection SNRs was considered meticulously. We do this all because the usually cited SNR-expressions were derived for a too simple and unrealistic case, and moreover contain some wrong assumptions. We introduce a novel HD scheme for astronomical interferometry gaining an order of magnitude in sensitivity against conventional HD and calculate that it should trespass the sensitivity of DD interferometry in the N- and Q-bands for a spectral resolution of R=10000, and should do also for R=300 with doable technical improvements. This result encourages to develop broad-band heterodyne technologies for future mid-infrared interferometry facilities and for new instruments at existing facilities.

Explore related subjects

Keep this discovery

BibTeXRIS

E. A. Michael, F. E. Besser, M. Hadjara, E. Moreno, A. Berdja, M. Pina, G. Pereira. 2023-12-22. An ab-initio derivation to discuss the heterodyne versus direct detection decision problem for astronomical infrared interferometry. https://arxiv.org/abs/2312.14365

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det