Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV

Abstract

The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and wavelength-shifting (WLS) technologies and photosensor, including SiPM and SiPM-like technology. The modules discussed herein consist of alternating layers of very dense (W) absorber and scintillating crystal (LYSO:Ce) plates, assembled to a depth of 25 $X_0$. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream and downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, and fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: $\sigma_{t} = a/\sqrt{E} \oplus b$, where a = 256 $\sqrt{GeV}$~ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be $\sigma_{t}$ = 27 ps.

Explore related subjects

Keep this discovery

BibTeXRIS

Carlos Perez-Lara, James Wetzel, Ugur Akgun, Thomas Anderson, Thomas Barbera, Dylan Blend, Kerem Cankocak, Salim Cerci, Nehal Chigurupati, Bradley Cox, Paul Debbins, Max Dubnowski, Buse Duran, Gizem Gul Dincer, Selbi Hatipoglu, Ilknur Hos, Bora Isildak, Colin Jessop, Ohannes Kamer Koseyan, Ayben Karasu Uysal, Reyhan Kurt, Berkan Kaynak, Alexander Ledovskoy, Alexi Mestvirishvili, Yasar Onel, Suat Ozkorucuklu, Aldo Penzo, Onur Potok, Daniel Ruggiero, Randal Ruchti, Deniz Sunar Cerci, Ali Tosun, Mark Vigneault, Yuyi Wan, Mitchell Wayne, Taylan Yetkin, Liyuan Zhang, Renyuan Zhu, Caglar Zorbilmez. 2024-01-03. Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV. https://arxiv.org/abs/2401.01747

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det