Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70

Abstract

In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.

Explore related subjects

Keep this discovery

BibTeXRIS

Masahiro Yoshimoto, Naoki Fukuda, Riku Matsumura, Daiki Nishimura, Hideaki Otsu, Yohei Shimizu, Toshiyuki Sumikama, Hiroshi Suzuki, Hiroyuki Takahashi, Hiroyuki Takeda, Junki Tanaka, Koichi Yoshida. 2024-01-11. Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70. https://arxiv.org/abs/2401.08679

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det