SearcharxivSearch

arXiv · 2401.16882

Prototype Cherenkov Detector Characterization for Muon Tomography Applications

Abstract

Muography is an innovative imaging technique using naturally produced elementary particles -- atmospheric muons -- like the X-rays of medical imaging. The modification of the particles flux -- by scattering or absorption --, reflects the contrasts in density within the medium and therefore offers the possibility for an image of the crossed volumes. The imaging process is based on the tracking of the particles which accounts for the absorption or the scattering of the muons trajectories. Neither the energy nor the identity of the particles (the so-called PID) is exploited since this information traditionally relies on the use of calorimeters and/or high intensity magnetic fields. Both these techniques hinder detector portability which in the case of muography is important and this renders them impractical for its purpose. In this paper we characterize the performance of a simple and small water Cherenkov detector capable on the one hand of providing some insights on energy and PID and on the other hand of improving the background rejection for a muon telescope. We tested a prototype of such water Cherenkov detector in combination with two small muon hodoscopes. Both systems are using the same opto-electronics chain -- optical fibers and pixellized photosensors -- and the same data acquisition (DAQ) readout system which ensures an easy integration and implementation within presently running systems. This article presents the test setup, the detector response to cosmic muons and its performance evaluation against a basic simulation of its geometry and detection principle.

Explore related subjects

Keep this discovery

BibTeXRIS

Theodore Avgitas, Jean Christophe Ianigro, Jacques Marteau. 2024-01-30. Prototype Cherenkov Detector Characterization for Muon Tomography Applications. https://arxiv.org/abs/2401.16882

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det