SearcharxivSearch

arXiv · 2501.07603

Characterization of Multiple Channels Room Temperature Readout Electronics for Large Transition-Edge Sensor Array

Abstract

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is through time-division multiplexing (TDM) direct current superconducting quantum interference device (SQUID). In a TDM system, the signal readout chain represents a significant source of noise other than the TES intrinsic noise. The noise generated by TES is in the range of several tens to several hundreds of $pA/\sqrt{Hz}$. In order to ensure the high energy resolution of TES, it is necessary to ensure that the noise contribution from the room temperature readout electronics is less than $10$ $pA/\sqrt{Hz}$ above 100 $Hz$. In this work, we have designed a low-noise, high-resolution room temperature readout circuit for TDM. The equivalent current noise contribution of ADC is about $0.05$ $pA/\sqrt{Hz}$ above 100 $Hz$ and $0.46$ $pA\sqrt{Hz}$ under 30:1 multiplexing. The resolution of the analog to digital converter (ADC) is larger than 11.5 bits, which can reconstruct the TES signal without distortion. The readout board, which has eight channels, has JESD204B serial ports, which has greatly simplified the space of room temperature electronics. The readout chain is based on multi-threaded CPU processing and can transfer data at 2 $Gbps$ for each channel in real time. This readout board can be used in a TDM system with smaller size for large TES arrays.

Explore related subjects

Keep this discovery

BibTeXRIS

N. Li, X. Ren, H. Gao, Z. Zhang, Y. Zhang, C. Liu, H. Li, Z. Li. 2025-01-11. Characterization of Multiple Channels Room Temperature Readout Electronics for Large Transition-Edge Sensor Array. https://arxiv.org/abs/2501.07603

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det