Demonstration of a mechanical external biventricular assist device for resuscitative thoracotomy

Abstract

Resuscitative thoracotomy, a high-risk procedure involving open heart massage, serves as a last resort for life-threatening conditions like penetrating chest wounds, severe blunt trauma, or surgery-related cardiac arrest. However, its success rate remains low, even with highly trained specialists. This research investigates the potential of an external biventricular assist device (BiVAD). By replacing open heart massage with our BiVAD device during resuscitative thoracotomy, we aim to achieve sufficient cardiac output, maintain physiological pressure levels, and potentially improve patient survival in these critical situations. The proposed BiVAD system features a simple 3D printed patch design for direct cardiac attachment, an actuation device, and a vacuum pump. The straightforward design allows quick application in emergency situations. The BiVAD system was tested in a hydraulic mock circulation, utilizing a silicone heart. Three actuation modes were tested for proof-of-concept: manual patch actuation, standard cardiac hand massage, and utilizing full capabilities of our BiVAD patch system with actuation device operation. Overall performance was assessed on ventricular pressure and flow rate data. Focusing on achieving the optimal cardiac output of 1.5 L/min (critical for patient survival), we tested our patch system against cardiac hand massage at a fixed rate of 60 bpm. Notably, our BiVAD system not only achieved to operate in the range of required cardiac output but also significantly reduced peak pressure in both ventricles compared to standard cardiac hand massage. This initial evaluation using a silicone heart model demonstrates the potential of our BiVAD system to achieve sufficient cardiac output while reducing peak pressure compared to cardiac hand massage. Further development holds promise for effective cardiac support in resuscitative thoracotomy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kristóf Sárosi, Thomas Kummer, Thomas Rösgen, Stijn Vandenberghe, Stefanos Demertzis, Patrick Jenny. 2025-03-18. Demonstration of a mechanical external biventricular assist device for resuscitative thoracotomy. https://arxiv.org/abs/2503.14087

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph