SearcharxivSearch

arXiv · 2503.18735

Design, Development and Testing of a Conformal 60 GHz Active Repeater for High Energy Physics Applications

Abstract

The Wireless Allowing Data and Power Transmission (WADAPT) proposal was formed to study the feasibility of wireless technologies in HEP experiments. A strong motivation for using wireless data transmission at the ATLAS detector is the absence of wires and connectors to reduce the passive material. However, the tracking layers are almost hermetic, acting as a Faraday cage, that doesn't allow propagation between the layers. For radial readout of the detector data through the layers, we have developed an active repeater board, which is passed through a 2-3 mm wide slit between the modules on the tracking layers. The repeater is also advantageous in building topological radial networks for neuromorphic tracking. The active repeater board consists of an RX antenna, an amplifier, and a TX antenna, and is tested on a mockup in a way that the RX antenna will be on the inner side of a module, and the TX antenna will be on the outer side of the same module, as the 10-mil thick conformal board is passed through the small slit. Transmission through the tracking layers using the repeater has been demonstrated with two horn antennas, a signal generator, and a spectrum analyzer. For 20 cm distance between the horn antenna and the repeater board, a receive level of -19.5 dBm was achieved. In comparison, with the same setup but with the amplifier turned off, the receive level was ~-46 dBm. The results show a significant milestone towards the implementation of 60 GHz links for detector data readout.

Explore related subjects

Keep this discovery

BibTeXRIS

Imran Aziz, Yasin Alekajbaf, Dragos Dancila, Kristiaan Pelckmans, Abhinav Jain, Richard Brenner. 2025-03-24. Design, Development and Testing of a Conformal 60 GHz Active Repeater for High Energy Physics Applications. https://arxiv.org/abs/2503.18735

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det