SearcharxivSearch

arXiv · 2505.21902

Rise Time and Charge Collection Efficiency of Graphene-Optimized 4H-SiC p-i-n Detector

Abstract

Silicon carbide detectors exhibit good detection performance and are being considered for detection applications. However, the presence of surface electrode of detector limits the application of low-penetration particle detectors, photodetectors and heavy-ion detection. A graphene-optimized 4H-SiC detector has been fabricated to expand the application of SiC detectors.Its electrical properties and the charge collection performance of {\alpha} particles are reported. The effective doping concentration of lightly doped 4H-SiC epitaxial layer is about 4.5\times10^{13}cm^{-3}, approaching the limit of the lowest doping level by the SiC epitaxial growth technique. The rise time of the graphene-optimized ring electrode detector is reduced by 24% at 200 V, compared to ring electrode detector. The charge collection efficiency (CCE) of graphene-optimized 4H-SiC PIN is 99.22%. When the irradiation dose is 2\times10^{11} n_{eq}/cm^2, the irradiation has no significant impact on the rise time and uniformity of the rise time for the graphene-optimized 4H-SiC detectors. This study proves that graphene has a certain radiation resistance. Graphene-optimized 4H-SiC detectors can not only reduce the signal rise time, but also improve uniformity of signal rise time and stability of charge collection. This research will expand the application of graphene-based 4H-SiC detectors in fields such as low energy ions, X-ray, UV light detection, particle physics, medical dosimetry and heavy-ion detection.

Explore related subjects

Keep this discovery

BibTeXRIS

Zhenyu Jiang, Xuemei Lu, Congcong Wang, Yingjie Huang, Xiaoshen Kang, Suyu Xiao, Xiyuan Zhang, Xin Shi. 2025-05-28. Rise Time and Charge Collection Efficiency of Graphene-Optimized 4H-SiC p-i-n Detector. https://arxiv.org/abs/2505.21902

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det