SearcharxivSearch

arXiv · 2506.03787

Effect of chromatic dispersion on image size and lattice plane curvature measurements with Rocking Curve Imaging

Abstract

ADP crystals of large dimensions (80x80x20 mm3), to be used as a X-ray beam expanders in the BEaTriX facility at INAF-OABrera, have been characterised at BM05 beamline at ESRF synchrotron with the main purpose to determine lattice plane curvature with a unprecedent accuracy, as the BEaTriX setup requires a radius of curvature larger than 22 km. In this beamline, the monochromator is made by 2 Si(111) parallel crystals in the non-dispersive configuration. Due to the difference in the Bragg angles between the Si(111) monochromator and the ADP(008) diffractions, only a limited part of the sample area, hit by the X-ray beam (11x11 mm2 cross section), produced a diffracted beam for a given value of angle of incidence. In the rocking curve imaging techniques, a full image of the sample for a given peak position is obtained by combining images taken at different angles of incidence compensated by the dispersion correction, that is the Bragg condition difference in different points of the sample. It is found that the resulting image size parallel to the scattering plane is affected by this dispersion correction. A 4.5 % elongation along the scattering plane was evaluated in the present Bragg case. This contribution is opposite in the Laue case.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elena Ferrari, Claudio Ferrari, Josè Baruchel, Thu Ni Tran Caliste, Stefano Basso, Akanshu Chauhan, Bianca Salmaso, Davide Sisana, Daniele Spiga. 2025-06-04. Effect of chromatic dispersion on image size and lattice plane curvature measurements with Rocking Curve Imaging. https://arxiv.org/abs/2506.03787

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det