SearcharxivSearch

arXiv · 2508.12306

Inverse Weak measurement in SERF magnetometer

Abstract

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analysing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT/Hz1/2. Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

Explore related subjects

Keep this discovery

BibTeXRIS

Qian Cao, Liang Xu, Ziqian Yue, Jianqi Yang, Yueyang Zhai. 2025-08-17. Inverse Weak measurement in SERF magnetometer. https://arxiv.org/abs/2508.12306

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det