SearcharxivSearch

arXiv subjects

Andrea Cossettini

Publications and source records attributed to Andrea Cossettini.

At least 19 recordsLinked to original sources

A Wearable Multimodal Ultrasound+Inertial System for Real-Time Virtual Reality Interaction

A-mode ultrasound (US) is a promising sensing modality for Virtual Reality (VR) interaction, as it enables the mapping of muscular activity into control commands while retaining the benefits of wearable sensing. However, existing approaches still face limitations in terms of wearability and interaction complexity, often relying on external hardware such as cameras. In this work, we propose a fully wearable multimodal interface for real-time VR-interaction, based on concurrent US and inertial (accelerometry) sensing from the forearm and upper arm. The system is built on the WULPUS platform and integrates an end-to-end software framework for real-time acquisition, visualization, and communication with a Unity-based VR environment. A multimodal learning pipeline is introduced for concurrent hand pose and forearm position estimation in 2D space. The interface is evaluated through offline and online experiments with five subjects, during the execution of three functional tasks: cylinder grasping (gross motor) and relocation, marble pinching (fine motor) and relocation, and liquid pouring. For offline experiments, we collect 5 acquisition sessions across multiple days, achieving an average inter-session accuracy across subjects of 80$\pm$6\% for hand pose estimation and 77$\pm$7\% for forearm position estimation. Online validation with minimal fine-tuning (5 min) demonstrates success rates of 92.0$\pm$16.0\%, 88.0$\pm$9.8\%, and 96.0$\pm$8.0\% for the three tasks, respectively. With a power consumption of only 19.9~mW, our system enables more than 2.5 days of continuous use on a small 350 mAh LiPo battery without the need for recharge, enabling truly wearable, multimodal, and functionally meaningful VR interaction.

eess.SY

WULPUS PRO: Multi-mode Ultra-Low-Power Wearable Ultrasound and Array Imaging with CMUT Support

Wearable ultrasound enables continuous monitoring of physiological processes such as muscle dynamics, bladder volume, and cardiovascular activity. Existing fully wearable ultra-low-power platforms are limited to shallow, low-channel A-mode sensing, while larger multi-mode systems are too bulky and power-hungry for true wearability. We present WULPUS PRO, a runtime-programmable wearable ultrasound acquisition platform measuring $39\times21\times6 \mathrm{mm}$ and weighing $5 \mathrm{g}$. It integrates $30 \mathrm{V}$ excitation, 16 time-multiplexed channels, a low-noise receive front-end with up to $70 \mathrm{dB}$ gain, $9.9 \mathrm{MHz}$ bandwidth, time-gain compensation, and $32 \mathrm{dB}$ SNR. The platform supports deep-tissue echo acquisition up to $2.2 \mathrm{MHz}$ in RF-sampling mode and $8 \mathrm{MHz}$ in envelope-detection mode. We demonstrate B-mode imaging in a 16-channel ultra-low-power wearable with sub-millimeter axial and millimeter-scale lateral resolution in phantom experiments, while consuming $40 \mathrm{mW}$ at $50 \mathrm{Hz}$ PRF and under $60 \mathrm{mW}$ at $300 \mathrm{Hz}$ PRF. WULPUS PRO supports both piezoelectric and capacitive micromachined ultrasonic transducers, enabling integration with skin-conformal polymer-based CMUT arrays. As a host-agnostic acquisition front-end, it exposes standard data and power interfaces for BLE- and Wi-Fi-based wearable hosts. We demonstrate wireless transmission with external BLE and Wi-Fi modules and project 1-2 days of BLE operation at $50 \mathrm{Hz}$ PRF and over 3 h of Wi-Fi streaming at $300 \mathrm{Hz}$ PRF using a $300 \mathrm{mAh}$, $6.4 \mathrm{g}$ Li-Po cell. WULPUS PRO establishes a new class of fully programmable, B-mode-enabled, ultra-low-power wearable ultrasound platforms.

eess.SY

Towards Whole Hand and Wrist Kinematic Tracking with a Wearable A-Mode Ultrasound Probe

A-mode ultrasound (US) has emerged as a promising modality for hand and wrist motion tracking. Prior works have mainly addressed static gesture classification or regression of a few degrees of freedom (DoFs), typically relying on non-wearable systems and external computing devices, and highlight the need for strategies to ensure robustness to sensor repositioning. In this work, we propose a framework for robust whole-hand and wrist kinematic tracking via wearable A-mode US using the WULPUS platform, tackling the regression of 23 DoFs directly on the probe. First, we introduce a compact (11285 parameters) multi-output convolutional neural network combined with an incremental training strategy, which improves inter-session generalization and reduces mean absolute error by more than 17% compared to a non-incremental approach. Second, we demonstrate, for the first time, the feasibility of end-to-end hand and wrist kinematic tracking entirely on-device. We deploy the model on the WULPUS nRF52832 microcontroller, achieving 0.73 mJ per inference, 29.1 ms latency, and showing the feasibility of full operation (data acquisition, online inference, and BLE streaming of results) within 33 mW, enabling up to 36 hours of continuous use and an 88% reduction in wireless bandwidth compared to raw data transmission.

eess.SP

Evaluation of EEG Foundation Models for Event-Based Burst-Suppression Detection in ICU

Burst suppression (BS) is a clinically relevant electroencephalographic (EEG) pattern used to monitor sedation depth and brain activity in critically ill patients, particularly during induced coma in Intensive Care Units (ICUs). Automatic burst detection remains challenging because BS patterns vary substantially between patients and annotated datasets are scarce. Recently, EEG Foundation Models (FMs) have shown promise across several downstream EEG applications, but their usefulness for BS detection remains unexplored. We present the first study to evaluate EEG FMs for burst detection in reduced-montage ICU EEG without patient-specific calibration. We compare REVE-base, LUNA-large and LuMamba-Tiny with an adaptive thresholding baseline and a task-specific EEGNet baseline. Additionally, we complement conventional EEG window-based classification with event-based burst detection evaluation. This helps assessing clinically whether burst episodes are correctly detected, reducing the impact of expected annotation variability. The best model, REVE-base, achieved the highest event-based F1-score ($0.868 \pm 0.167$) and reduced burst-per-minute error by 52.1% and 36.2% compared to EEGNet and adaptive thresholding respectively, supporting FMs for scalable EEG monitoring in ICU. Ablation experiments showed that full fine-tuning was the most effective adaptation strategy with respect to frozen-backbone training, two-step fine-tuning, and LoRA-based adaptation, improving event-based F1-score over frozen-backbone training by up to $+0.102$ for LUNA-large. With reduced labeled datasets, pretrained REVE-base outperformed random initialization by $+0.723$ event-based F1 points at 25% of the cohort, demonstrating the benefit of pretraining FM representations when adapted to burst detection with limited labeled data.

eess.SP

Polymer-based Capacitive Micromachined Transducer-Enabled Inline Monitoring of Ultrasonic Welding in Thermoplastic Carbon Fiber Composites

Thermoplastic composite structures enable lightweight, recyclable, and high-throughput aerospace manufacturing, but reliable quality assurance of advanced joining processes remains a key challenge. This work presents a compact, low-cost, and wireless ultrasonic non-destructive testing system for real-time, inline monitoring of continuous ultrasonic welding of thermoplastic carbon fiber composites. The system integrates custom-fabricated polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs) with the ultra-low-power WULPUS platform, enabling operation in the harsh, high-interference welding environment. An eight-element linear polyCMUT array operating at a center frequency of approximately 3.6 MHz is designed, fabricated, packaged, and integrated into an industrial welding setup. Inline measurements are performed during welding of carbon fiber laminates with intentionally introduced defects. Process-synchronous ultrasonic data reveal consistent depth-of-echo shifts at defect locations, in strong agreement with X-ray computed tomography ground truth. Across 21 welds, all induced defects are detected without false negatives and with limited false positives. The results demonstrate that polymer-based CMUT technology enables robust, scalable, and manufacturing-compatible ultrasonic sensing, representing a decisive step toward intelligent process monitoring and quality assurance for next-generation thermoplastic composite welding.

eess.SY

FEMBA on the Edge: Physiologically-Aware Pre-Training, Quantization, and Deployment of a Bidirectional Mamba EEG Foundation Model on an Ultra-low Power Microcontroller

Objective: To enable continuous, long-term neuro-monitoring on wearable devices by overcoming the computational bottlenecks of Transformer-based Electroencephalography (EEG) foundation models and the quantization challenges inherent to State-Space Models (SSMs). Methods: We present FEMBA, a bidirectional Mamba architecture pre-trained on over 21,000 hours of EEG. We introduce a novel Physiologically-Aware pre-training objective, consisting of a reconstruction with low-pass filtering, to prioritize neural oscillations over high-frequency artifacts. To address the activation outliers common in SSMs, we employ Quantization-Aware Training (QAT) to compress the model to 2-bit weights. The framework is deployed on a parallel ultra-low-power RISC-V microcontroller (GAP9) using a custom double-buffered memory streaming scheme. Results: The proposed low-pass pre-training improves downstream AUROC on TUAB from 0.863 to 0.893 and AUPR from 0.862 to 0.898 compared to the best contrastive baseline. QAT successfully compresses weights with negligible performance loss, whereas standard post-training quantization degrades accuracy by approximately \textbf{30\%}. The embedded implementation achieves deterministic real-time inference (\textbf{1.70~s} per 5~s window) and reduces the memory footprint by \textbf{74\%} (to $\approx$2~MB), achieving competitive accuracy with up to \textbf{27$\times$} fewer FLOPs than Transformer benchmarks. Conclusion: FEMBA demonstrates that Mamba-based foundation models can be effectively quantized and deployed on extreme-edge hardware without sacrificing the representation quality required for robust clinical analysis. Significance: This work establishes the first full-stack framework for deploying large-scale EEG foundation models on ultra-low-power wearables, facilitating continuous, SSM based monitoring for epilepsy and sleep disorders.

eess.SP

SilentWear: an Ultra-Low Power Wearable System for EMG-based Silent Speech Recognition

Detecting speech from biosignals is gaining increasing attention due to the potential to develop human-computer interfaces that are noise-robust, privacy-preserving, and scalable for both clinical applications and daily use. However, most existing approaches remain limited by insufficient wearability and the lack of edge-processing capabilities, which are essential for minimally obtrusive, responsive, and private assistive technologies. In this work, we present SilentWear, a fully wearable, textile-based neck interface for EMG signal acquisition and processing. Powered by BioGAP-Ultra, the system enables end-to-end data acquisition from 14 differential channels and on-device speech recognition. SilentWear is coupled with SpeechNet, a lightweight 15k-parameter CNN architecture specifically tailored for EMG-based speech decoding, achieving an average cross-validated accuracy of 84.8$\pm$4.6% and 77.5$\pm$6.6% for vocalized and silent speech, respectively, over eight representative human-machine interaction commands collected over multiple days. We evaluate robustness to repositioning induced by multi-day use. In an inter-session setting, the system achieves average accuracies of 71.1$\pm$8.3% and 59.3\pm2.2% for vocalized and silent speech, respectively. To mitigate performance degradation due to repositioning, we propose an incremental fine-tuning strategy, demonstrating more than 10% accuracy recovery with less than 10 minutes of additional user data. Finally, we demonstrate end-to-end real-time on-device speech recognition on a commercial multi-core microcontroller unit (MCU), achieving an energy consumption of 63.9$μ$J per inference with a latency of 2.47 ms. With a total power consumption of 20.5mW for acquisition, inference, and wireless transmission of results, SilentWear enables continuous operation for more than 27 hours.

eess.SP

Validation of a Software-Defined 100-Gb/s RDMA Streaming Architecture for Ultrafast Optoacoustic and Ultrasound Imaging

Optoacoustic (OA) imaging has emerged as a powerful investigation tool, with demonstrated applicability in oncology, neuroscience, and cardiovascular biology. However, its clinical translation is limited with the existing OA systems, which often rely on bulky and expensive acquisition hardware mainly optimized for pulse-echo ultrasound (US) imaging. Despite the fact that OA imaging has different requirements for receive bandwidths and timing synchronization with external laser sources, there is a strong need for unified OA-US imaging platforms, as pulse-echo US remains the standard tool for visualizing soft tissues. To address these challenges, we propose a new data acquisition architecture for ultrafast OA and US imaging that fully covers the requirements for large channel counts, wide bandwidth, and software-defined operation. LtL combines state-of-the-art wideband analog front-ends, a Zynq UltraScale+ MPSoC integrating FPGA fabric with an Application Processing Unit, and a 100 GbE Remote Direct Memory Access (RDMA) backend enabling raw-data streaming at up to 95.6 Gb/s. The architecture avoids local buffers followed by burst transfers, which commonly constrain sustainable frame rate and recording intervals, thus achieving true continuous and sustained streaming of raw data. We validate the core elements of the LtL architecture using a 16-channel demonstration system built from commercial evaluation boards. We further verify the signal chain for up to 256-channel scalability, confirming the wide bandwidth capabilities to support state-of-the-art data transmission speeds.

eess.SY

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

Objective: Surface electromyography (EMG) is a non-invasive sensing modality widely used in biomechanics, rehabilitation, prosthetic control, and human-machine interfaces. Despite decades of use, achieving robust generalization across subjects, recording systems, and acquisition protocols remains challenging. While foundation models (FMs) are gaining traction for EMG, existing approaches remain limited to single downstream tasks and lack deployability on embedded platforms. This work addresses these limitations. Methods: We present TinyMyo, a lightweight FM based on a Transformer encoder architecture. The model is pre-trained in a self-supervised manner using masked reconstruction on publicly available datasets. With only 3.6M parameters, TinyMyo is designed to support multiple downstream tasks through minimal task-specific head adaptations. Results: We demonstrate generalization across hand gesture classification, hand kinematic regression, speech production and speech recognition, with performance comparable to or surpassing the state of the art (SoA), and model size below 5M parameters. We achieve SoA results compared to previous FM-based works on the NinaPro DB5 (89.4%), UCI-EMG (97.56%), and EPN-612 (96.74%) datasets. We demonstrate the first-time deployment of an EMG FM on an ultra-low power microcontroller (GAP9), with an inference time of 0.785 s, energy of 44.91 mJ and power envelope of 57.18 mW. Conclusion: TinyMyo demonstrates that compact, self-supervised EMG FM can guarantee strong generalization across multiple downstream tasks while remaining compatible with low-power edge devices. Significance: TinyMyo is the first EMG FM for ultra-low power edge devices, enabling scalable and energy-efficient sensing for motor intent decoding, neuromuscular assessment, and biosignal driven human-machine interaction.

eess.SP

GAPses: Versatile smart glasses for comfortable and fully-dry acquisition and parallel ultra-low-power processing of EEG and EOG

Recent advancements in head-mounted wearable technology are revolutionizing the field of biopotential measurement, but the integration of these technologies into practical, user-friendly devices remains challenging due to issues with design intrusiveness, comfort, and data privacy. To address these challenges, this paper presents GAPses, a novel smart glasses platform designed for unobtrusive, comfortable, and secure acquisition and processing of electroencephalography (EEG) and electrooculography (EOG) signals. We introduce a direct electrode-electronics interface with custom dry soft electrodes to enhance comfort for long wear. An integrated parallel ultra-low-power RISC-V processor (GAP9, Greenwaves Technologies) processes data at the edge, thereby eliminating the need for continuous data streaming through a wireless link, enhancing privacy, and increasing system reliability in adverse channel conditions. We demonstrate the broad applicability of the designed prototype through validation in a number of EEG-based interaction tasks, including alpha waves, steady-state visual evoked potential analysis, and motor movement classification. Furthermore, we demonstrate an EEG-based biometric subject recognition task, where we reach a sensitivity and specificity of 98.87% and 99.86% respectively, with only 8 EEG channels and an energy consumption per inference on the edge as low as 121 $μJ$. Moreover, in an EOG-based eye movement classification task, we reach an accuracy of 96.68% on 11 classes, resulting in an information transfer rate of 94.78 bit/min, which can be further increased to 161.43 bit/min by reducing the accuracy to 81.43%. The deployed implementation has an energy consumption of 40 $μJ$ per inference and a total system power of only 12.4 mW, of which only 1.61% is used for classification, allowing for continuous operation of more than 22 h with a small 75 mAh battery.

eess.SP

BioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing

The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage (x2 SRAM, x4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, x4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels (x2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system's versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.

eess.SY

CEReBrO: Compact Encoder for Representations of Brain Oscillations Using Efficient Alternating Attention

Electroencephalograph (EEG) is a crucial tool for studying brain activity. Recently, self-supervised learning methods leveraging large unlabeled datasets have emerged as a potential solution to the scarcity of widely available annotated EEG data. However, current methods suffer from at least one of the following limitations: i) sub-optimal EEG signal modeling, ii) model sizes in the hundreds of millions of trainable parameters, and iii) reliance on private datasets and/or inconsistent public benchmarks, hindering reproducibility. To address these challenges, we introduce a Compact Encoder for Representations of Brain Oscillations using alternating attention (CEReBrO), a new small EEG foundation model. Our tokenization scheme represents EEG signals at a per-channel patch granularity. We propose an alternating attention mechanism that jointly models intra-channel temporal dynamics and inter-channel spatial correlations, achieving 2x speed improvement with 6x less memory required compared to standard self-attention. We present several model sizes ranging from 3.6 million to 85 million parameters. Pre-trained on over 20,000 hours of publicly available scalp EEG recordings with diverse channel configurations, our models set new benchmarks in emotion detection and seizure detection tasks, with competitive performance in anomaly classification and gait prediction. This validates our models' effectiveness and efficiency.

cs.LG

Wearable and Ultra-Low-Power Fusion of EMG and A-Mode US for Hand-Wrist Kinematic Tracking

Hand gesture recognition based on biosignals has shown strong potential for developing intuitive human-machine interaction strategies that closely mimic natural human behavior. In particular, sensor fusion approaches have gained attention for combining complementary information and overcoming the limitations of individual sensing modalities, thereby enabling more robust and reliable systems. Among them, the fusion of surface electromyography (EMG) and A-mode ultrasound (US) is very promising. However, prior solutions rely on power-hungry platforms unsuitable for multi-day use and are limited to discrete gesture classification. In this work, we present an ultra-low-power (sub-50 mW) system for concurrent acquisition of 8-channel EMG and 4-channel A-mode US signals, integrating two state-of-the-art platforms into fully wearable, dry-contact armbands. We propose a framework for continuous tracking of 23 degrees of freedom (DoFs), 20 for the hand and 3 for the wrist, using a kinematic glove for ground-truth labeling. Our method employs lightweight encoder-decoder architectures with multi-task learning to simultaneously estimate hand and wrist joint angles. Experimental results under realistic sensor repositioning conditions demonstrate that EMG-US fusion achieves a root mean squared error of $10.6^\circ\pm2.0^\circ$, compared to $12.0^\circ\pm1^\circ$ for EMG and $13.1^\circ\pm2.6^\circ$ for US, and a R$^2$ score of $0.61\pm0.1$, with $0.54\pm0.03$ for EMG and $0.38\pm0.20$ for US.

eess.SP

A Parallel Ultra-Low Power Silent Speech Interface based on a Wearable, Fully-dry EMG Neckband

We present a wearable, fully-dry, and ultra-low power EMG system for silent speech recognition, integrated into a textile neckband to enable comfortable, non-intrusive use. The system features 14 fully-differential EMG channels and is based on the BioGAP-Ultra platform for ultra-low power (22 mW) biosignal acquisition and wireless transmission. We evaluate its performance on eight speech commands under both vocalized and silent articulation, achieving average classification accuracies of 87$\pm$3% and 68$\pm$3% respectively, with a 5-fold CV approach. To mimic everyday-life conditions, we introduce session-to-session variability by repositioning the neckband between sessions, achieving leave-one-session-out accuracies of 64$\pm$18% and 54$\pm$7% for the vocalized and silent experiments, respectively. These results highlight the robustness of the proposed approach and the promise of energy-efficient silent-speech decoding.

eess.SY

ListenToJESD204B: A Lightweight Open-Source JESD204B IP Core for FPGA-Based Ultrasound Acquisition systems

The demand for hundreds of tightly synchronized channels operating at tens of MSPS in ultrasound systems exceeds conventional low-voltage differential signaling links' bandwidth, pin count, and latency. Although the JESD204B serial interface mitigates these limitations, commercial FPGA IP cores are proprietary, costly, and resource-intensive. We present ListenToJESD204B, an open-source receiver IP core released under a permissive Solderpad 0.51 license for AMD Xilinx Zynq UltraScale+ devices. Written in synthesizable SystemVerilog, the core supports four GTH/GTY lanes at 12.8 Gb/s and provides cycle-accurate AXI-Stream data alongside deterministic Subclass~1 latency. It occupies only 107 configurable logic blocks (approximately 437 LUTs), representing a 79\% reduction compared to comparable commercially available IP. A modular data path featuring per-lane elastic buffers, SYSREF-locked LMFC generation, and optional LFSR descrambling facilitates scaling to high lane counts. We verified protocol compliance through simulation against the Xilinx JESD204C IP in JESD204B mode and on hardware using TI AFE58JD48 ADCs. Block stability was verified by streaming 80 MSPS, 16-bit samples over two 12.8 Gb/s links for 30 minutes with no errors.

cs.AR

Real-Time, Single-Ear, Wearable ECG Reconstruction, R-Peak Detection, and HR/HRV Monitoring

Biosignal monitoring, in particular heart activity through heart rate (HR) and heart rate variability (HRV) tracking, is vital in enabling continuous, non-invasive tracking of physiological and cognitive states. Recent studies have explored compact, head-worn devices for HR and HRV monitoring to improve usability and reduce stigma. However, this approach is challenged by the current reliance on wet electrodes, which limits usability, the weakness of ear-derived signals, making HR/HRV extraction more complex, and the incompatibility of current algorithms for embedded deployment. This work introduces a single-ear wearable system for real-time ECG (Electrocardiogram) parameter estimation, which directly runs on BioGAP, an energy-efficient device for biosignal acquisition and processing. By combining SoA in-ear electrode technology, an optimized DeepMF algorithm, and BioGAP, our proposed subject-independent approach allows for robust extraction of HR/HRV parameters directly on the device with just 36.7 uJ/inference at comparable performance with respect to the current state-of-the-art architecture, achieving 0.49 bpm and 25.82 ms for HR/HRV mean errors, respectively and an estimated battery life of 36h with a total system power consumption of 7.6 mW. Clinical relevance: The ability to reconstruct ECG signals and extract HR and HRV paves the way for continuous, unobtrusive cardiovascular monitoring with head-worn devices. In particular, the integration of cardiovascular measurements in everyday-use devices (such as earbuds) has potential in continuous at-home monitoring to enable early detection of cardiovascular irregularities.

eess.SP

Train-On-Request: An On-Device Continual Learning Workflow for Adaptive Real-World Brain Machine Interfaces

Brain-machine interfaces (BMIs) are expanding beyond clinical settings thanks to advances in hardware and algorithms. However, they still face challenges in user-friendliness and signal variability. Classification models need periodic adaptation for real-life use, making an optimal re-training strategy essential to maximize user acceptance and maintain high performance. We propose TOR, a train-on-request workflow that enables user-specific model adaptation to novel conditions, addressing signal variability over time. Using continual learning, TOR preserves knowledge across sessions and mitigates inter-session variability. With TOR, users can refine, on demand, the model through on-device learning (ODL) to enhance accuracy adapting to changing conditions. We evaluate the proposed methodology on a motor-movement dataset recorded with a non-stigmatizing wearable BMI headband, achieving up to 92% accuracy and a re-calibration time as low as 1.6 minutes, a 46% reduction compared to a naive transfer learning workflow. We additionally demonstrate that TOR is suitable for ODL in extreme edge settings by deploying the training procedure on a RISC-V ultra-low-power SoC (GAP9), resulting in 21.6 ms of latency and 1 mJ of energy consumption per training step. To the best of our knowledge, this work is the first demonstration of an online, energy-efficient, dynamic adaptation of a BMI model to the intrinsic variability of EEG signals in real-time settings.

eess.SP

An Ultra-Low Power Wearable BMI System with Continual Learning Capabilities

Driven by the progress in efficient embedded processing, there is an accelerating trend toward running machine learning models directly on wearable Brain-Machine Interfaces (BMIs) to improve portability and privacy and maximize battery life. However, achieving low latency and high classification performance remains challenging due to the inherent variability of electroencephalographic (EEG) signals across sessions and the limited onboard resources. This work proposes a comprehensive BMI workflow based on a CNN-based Continual Learning (CL) framework, allowing the system to adapt to inter-session changes. The workflow is deployed on a wearable, parallel ultra-low power BMI platform (BioGAP). Our results based on two in-house datasets, Dataset A and Dataset B, show that the CL workflow improves average accuracy by up to 30.36% and 10.17%, respectively. Furthermore, when implementing the continual learning on a Parallel Ultra-Low Power (PULP) microcontroller (GAP9), it achieves an energy consumption as low as 0.45mJ per inference and an adaptation time of only 21.5ms, yielding around 25h of battery life with a small 100mAh, 3.7V battery on BioGAP. Our setup, coupled with the compact CNN model and on-device CL capabilities, meets users' needs for improved privacy, reduced latency, and enhanced inter-session performance, offering good promise for smart embedded real-world BMIs.

eess.SP