SearcharxivSearch

arXiv · 2601.14321

High-Resolution Electron Paramagnetic Resonance

Abstract

Electron paramagnetic resonance (EPR) is a valuable tool for physics, chemistry, biology and medicine, providing complementary spectroscopic information to NMR. It has long been known that EPR at high magnetic fields offers greater spectral resolution, but limitations in the THz instrumentation have prevented the full realization of these opportunities. Here we describe an EPR spectrometer at the high magnetic field of 14 T using 396 GHz excitation, which adapts techniques from liquid-state NMR to obtain sharp EPR resonances with a width of 210 ppb (full-width half-maximum). We use this to measure resonance positions, and hence g-factors, with a precision that reaches $\pm$16 ppb. Our use of in-situ liquid-state NMR of our solvent within the same sample improves the accuracy of these measurements: it allows us to reference our EPR measurement back to dilute gas 3He NMR for which quantum calculations are accurate. We measure the g-factor of N@C60 in deuterated toluene as g = 2.002 099 09 (3), where the 3 in brackets means that the uncertainty on the last digit is $\pm$3.

Explore related subjects

Keep this discovery

BibTeXRIS

Colin J. Stephen, Anton Tcholakov, Maik Icker, Stuart M. Graham, Xiaoming Zhao, Robert Day, Jeanette Chattaway, T. John S. Dennis, Wolfgang Harneit, Gavin W. Morley. 2026-01-19. High-Resolution Electron Paramagnetic Resonance. https://arxiv.org/abs/2601.14321

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det