OptiGAN for Crystal Arrays: Physics-Informed Generative Modeling of Optical Photon Transport in PET Detector Arrays

Abstract

Monte Carlo simulations of optical photon transport are computationally prohibitive for large-scale optical systems including detector arrays and PET systems, restricting their practical use to single-crystal studies. This work presents an enhanced conditional generative adversarial network capable of replacing optical simulations at the crystal array level, extending our previous single-crystal approach to a 3x3 BGO detector array. We introduce Fourier feature encoding and a learnable latent mapping network as the modifications enabling stable training on the array geometry, together with a physics-informed loss term enforcing the unit-sphere state space $S^2$ of the generated propagation directions as a soft constraint. Training data requirements are reduced eight-fold by exploiting the array's symmetry. Performance is benchmarked against GATE10/Geant4 ground truth, using the fluctuations between independent Monte Carlo runs. The enhanced optiGAN achieves similarity values within 3$\sigma$ agreement of the Monte Carlo baseline across all evaluation conditions. An ablation and attribution analysis shows that the physics-informed loss term reduces low-SSIM bin fractions by a factor of 3.6 on the outer crystals, with a localized trade-off at the central crystal, yielding a net 48% reduction over the full array. The model transitions from electron-emission training data to realistic gamma-photon interactions, producing flood maps that reproduce experimental patterns including photopeak clusters and inter-crystal scatter lines. This proof-of-concept demonstrates that a physics-informed generative model can simulate optical photon transport in segmented scintillator arrays at a training and inference cost accessible on a single workstation GPU.

Explore related subjects

Keep this discovery

BibTeXRIS

Stephan Naunheim, Brandon Pardi, Guneet Mummaneni, Carlotta Trigila, Emilie Roncali. 2026-01-26. OptiGAN for Crystal Arrays: Physics-Informed Generative Modeling of Optical Photon Transport in PET Detector Arrays. https://doi.org/10.1088/1361-6560%2Fae95d7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det