SearcharxivSearch

arXiv · 2603.02369

Continual Learning via Ensemble-Based Depth-Wise Masked Autoencoders for Data Quality Monitoring in High-Energy Physics

Abstract

Machine learning (ML) techniques have been demonstrated to improve the accuracy and efficiency of anomaly detection (AD) when compared to conventional methods. This has led to the adoption of ML for data quality monitoring (DQM) use cases in order to monitor the operation of certain systems to ensure that they are free of undesirable or potentially deleterious anomalies. For applications in the field of High-Energy physics (HEP), where detectors must operate in long-running, harsh environments, ML models used in DQM that have been trained on static datasets are bound to experience degraded performance due to distributional shifts that naturally occur in the incoming data streams, unless directly mitigated via the inclusion of continual ML techniques. This work introduces DepthViT, a lightweight masked autoencoder architecture that employs unique depth-wise embeddings and depth-wise attention, to perform computationally efficient AD tasks. A continual learning framework is developed in which DepthViT models trained on the most recent data streams are ensembled with older models to create a robust overall system which is more resilient to shifts in incoming data streams. When evaluated on occupancy maps from the Compact Muon Solenoid (CMS) hadron calorimeter across multiple data-taking campaigns, the proposed method maintains precision above 98.8\% and a stable ratio of correct anomaly predictions to number of anomalies both under small and large distributional shifts. Beyond HEP, the same ensembling-based continual adaptation strategy can be directly applied to industrial monitoring environments where data also naturally evolve over time. This work therefore presents a path toward adaptive anomaly detection systems capable of sustained operation in dynamic data environments.

Explore related subjects

Keep this discovery

BibTeXRIS

Dale Julson, Eric Reinhardt, Andrii Krutsylo, Resham Sohal, Guillermo Fidalgo, Sergei Gleyzer, Emanuele Usai, The CMS HCAL Collaboration. 2026-03-02. Continual Learning via Ensemble-Based Depth-Wise Masked Autoencoders for Data Quality Monitoring in High-Energy Physics. https://arxiv.org/abs/2603.02369

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Production of Light Nuclei and Hypernuclei in Heavy-Ion Collisions

We review recent STAR and ALICE measurements of light-nucleus and hypernucleus yields, femtoscopic correlations, and collective flow presented at SQM 2026. Statistical-hadronization calculations provide a useful baseline for integrated yields but do not simultaneously describe all measured light-nucleus ratios across collision energies and system sizes. For bound states with mass number $A<4$, current coalescence calculations provide a broadly consistent description of yields, femtoscopic correlations, and collective flow, although the quantitative hypertriton comparison depends on the assumed few-body wave function. The suppressed production of resonant $^{4}$Li relative to compact $^{4}$He indicates an effect of nuclear structure and late-stage dynamics. However, the quantitative model comparison also depends on the treatment of feed-down from unstable states. In high-multiplicity $p$+$p$ collisions, pion-deuteron femtoscopy further indicates that most observed (anti)deuterons are formed through nucleon fusion after strong decays of short-lived resonances. Taken together, these measurements show that production chronology and internal nuclear structure leave measurable imprints on the physics observables.

hep-ex

Search for the process $e^+e^-\to f_1(1285)$ at the SND detector

In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider, a search is performed for the direct production of the $C$-even $f_1(1285)$ resonance in $e^+e^-$ collisions. The analysis is based on data with an integrated luminosity of about 200 pb$^{-1}$, accumulated in the center-of-mass energy range of 1.14--1.46 GeV, of which about 72 pb$^{-1}$ were recorded near the maximum of the $f_1(1285)$ resonance. The $f_1(1285)$ production cross section at the resonance maximum $\sigma(e^+e^-\to f_1)=(31\pm 13\pm 2)$ pb and the branching fraction $B(f_1(1285)\to e^+e^-)=(3.5\pm 1.4\pm 0.3)\times 10^{-9}$ have been measured. The significance of the observation of the $e^+e^-\to f_1(1285)$ process is $2.5\sigma$. Since the significance is low, we also present the upper limits at the 90% confidence level: $\sigma(e^+e^-\to f_1)<48\mbox{ pb}$ and $B(f_1(1285)\to e^+e^-)<5.4\times 10^{-9}$.

hep-ex

Projected Sensitivity to Slow Muonphilic Dark Matter with Accelerator Muon Beams

The nature of dark matter (DM) remains one of the most enduring open questions in modern physics, and muonphilic DM has emerged as a promising scenario that complements traditional DM candidates. Following the recently established cosmic-ray muon scattering approach, we investigate the sensitivity for probing slow muonphilic DM with accelerator muon beams. A Geant4-based simulation framework is developed, incorporating the detector geometry from the PKMu muon tomography system and a dedicated elastic $\mu$-DM scattering process. The projected sensitivity is found to be largely insensitive to both the beam energy and the transverse beam size when the beam is fully contained within the detector acceptance. For a benchmark beam intensity of $10^5/\rm{s}$, the simulated pure-muon beam surpasses the existing cosmic-ray limit of $1.61\times10^{-17}$ cm$^2$ at $m_{\rm DM}=1$ GeV within approximately 11 seconds. A realistic muon beam phase-space distribution based on simulations for the High Intensity heavy-ion Accelerator Facility (HIAF) is also implemented, yielding projected limits that improve upon the cosmic-ray results by nearly two orders of magnitude in a one-day exposure. These results demonstrate that a beam-muon scattering experiment offers a robust and promising route toward significantly improved sensitivity to slow muonphilic DM.

hep-ex