SearcharxivSearch

arXiv · 2603.27120

Time Resolution of a Novel Ultra-fast Graphene-Optimized 4H-SiC PIN

Abstract

Silicon carbide detectors exhibit good detection performance such as fast time resolution, high radiation tolerances, high breakdown voltage and low temperature sensitivity and have been studied for detection applications. Meanwhile, transient current technique (TCT) is a direct and effective method to evaluate the time resolution of semiconductor detectors. Conventional metal electrodes for TCT testing employ window structures, which lead to non-uniform electric field distribution and deteriorated time resolution. Graphene features high optical transmittance, ultrahigh carrier mobility, and excellent radiation resistance, making it an ideal transparent electrode material for semiconductor detectors. In this work, a graphene-optimized ring electrode (G/RE) 4H-SiC PIN detector and a reference ring electrode (RE) 4H-SiC PIN detector are fabricated. TCT measurements demonstrate that graphene integration improves the time resolution consistency, reducing the time resolution from 38 ps (reference RE detector) to 21 ps (G/RE detector) at the maximum scanning distance, while also achieving effective noise suppression. The graphene integration improves the stability of time resolution by 87% compared to the reference detector. Notably, the achieved time resolution of 21 ps is comparable to that of state-of-the-art 4H-SiC low-gain avalanche detectors (LGADs), which typically exhibit time resolutions better than 35 ps under single minimum ionizing particle (MIP) equivalent injection conditions, further validating the effectiveness of graphene-based electrode design.

Explore related subjects

Keep this discovery

BibTeXRIS

Suyu Xiao, Hui Liang, Congcong Wang, Zhenyu Jiang, Lin Zhu. 2026-03-28. Time Resolution of a Novel Ultra-fast Graphene-Optimized 4H-SiC PIN. https://arxiv.org/abs/2603.27120

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det