SearcharxivSearch

arXiv · 2606.05385

GPU optical photon Monte Carlo for noble liquid detectors: validation against Geant4 in a large liquid argon TPC benchmark

Abstract

Optical photon Monte Carlo simulation is a computational bottleneck for noble liquid Time Projection Chambers. Design studies require repeated, geometry dependent simulations of timing, wavelength shifting, and optical response, while reconstruction and particle identification workflows need labeled optical datasets. We present Simphony, a GPU optical simulation tool, formerly EIC-Opticks, built on Opticks with CUDA and NVIDIA OptiX. Simphony implements a GPU version of the Geant4 G4OpWLS wavelength-shifting model and returns Monte Carlo truth for detected hits with low per-photon overhead. We validate Simphony against Geant4 11.3.2 in a simplified 14.7 kt liquid argon Time Projection Chamber benchmark with a two-stage wavelength-shifting shell and idealized photon counting detector. For three paired 2.5 GeV electron simulations, each producing about 61 M optical photons, the integrated detected-photon ratio agrees with Geant at the subpercent level. The detected arrival time and wavelength spectra give $\chi^2/\mathrm{ndf}$ values of 0.98 and 1.08. Contained muon and near-Cerenkov-threshold proton samples give $R_N=1.0017\pm0.0008$ and $R_N=1.0005\pm0.0014$, confirming agreement for distinct source topologies. On an NVIDIA RTX 4090, a stacked launch of four 2.5 GeV electron events transports 243 M optical photons in $3.03\pm0.06$ s, giving $80.2\pm1.6$ M photons s$^{-1}$. Relative to a single-thread Geant reference and including GPU overheads and host-device transfers, the optical transport speedup is $1053\pm55$; the end-to-end wall time acceleration is $89\pm5$. These results show that Simphony can make explicit optical photon Monte Carlo practical for detector development studies and for generating machine learning optical response datasets.

Explore related subjects

Keep this discovery

BibTeXRIS

Gabor Galgoczi, Xuyang Ning, Dmitri Smirnov, Brett Viren, Chao Zhang. 2026-06-03. GPU optical photon Monte Carlo for noble liquid detectors: validation against Geant4 in a large liquid argon TPC benchmark. https://arxiv.org/abs/2606.05385

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det