SearcharxivSearch

arXiv · 2607.15492

Differentiable Cardiac Electrophysiology Simulations for Dynamical State and Parameter Estimation

Abstract

The heart's contractions are triggered by action potential waves, which propagate through the cardiac muscle and exhibit diverse spatio-temporal dynamics during different heart rhythms. The dynamics are modeled with partial differential equations (PDEs) in cardiac electrophysiology simulations. However, fitting such models to measurement data to develop digital twins or patient-specific computer models is challenging. Here, we introduce differentiable cardiac electrophysiology simulations that can be fitted automatically to spatio-temporal measurement data of action potential waves in cardiac tissue. By comparing the simulated dynamics with the observation data, we define a loss function that is minimized via gradient-based optimization. Backpropagating the loss gradient through the differentiable PDE solver enables us to learn the parameters and recover the full dynamics, even with sparse, noisy, or partial observations. Implemented using both the finite-difference and smoothed particle hydrodynamics methods, our simulation framework can be applied to pixel-, voxel-, or point-based data, such as 2D or 3D slabs, or arbitrary shapes, such as the heart's ventricles. Using this methodology, we locate early activation sites inside a 3D bi-ventricular simulation geometry and fit a phenomenological model to imaging data of a voltage spiral wave in a cardiac monolayer cell culture. With experimental data, we employed a perceptual loss based on the Video Joint-Embedding Predictive Architecture, which enables fitting to noisy imaging data, and a generative diffusion model to estimate initial conditions and constrain solutions. Differentiable cardiac electrophysiology simulations could improve the diagnosis of rhythm abnormalities in patients and facilitate the development of personalized models or digital twins of the heart.

Explore related subjects

Keep this discovery

BibTeXRIS

Adarsh Pashikanti, Shrey Chowdhary, Alex Ho, Weizhen Li, Emilia Entcheva, Jan Christoph. 2026-07-16. Differentiable Cardiac Electrophysiology Simulations for Dynamical State and Parameter Estimation. https://arxiv.org/abs/2607.15492

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph