SearcharxivSearch

arXiv · 2608.23141

A Cosmic Muon Tomography System with Machine Learning based Momentum Measurement for Multi-Object Reconstruction and Material Characterization

Abstract

Cosmic muon tomography is a powerful non-destructive imaging technique for inspecting dense and shielded materials through multiple Coulomb scattering. In this work, we present the design, simulation, and performance evaluation of a complete muon tomography system comprising six scintillator-strip tracking stations for trajectory reconstruction and a four-station magnetic spectrometer for muon momentum estimation. The detector geometry is implemented in the GEANT4 framework and optimized for object localization and material characterization. The reconstructed momentum is combined with the scattering angle to define the scattering density $\rho_s = {(\theta p)^2}/{L_{\mathrm{eff}}}$, which enhances sensitivity to material-dependent scattering. Point-of-Closest-Approach (PoCA) reconstruction is used to estimate scattering locations within the imaging volume. To detect and separate multiple unknown objects, Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN) is applied to the reconstructed PoCA cloud. Cluster-level scattering and geometric features are then extracted for object characterization. The proposed framework enables object detection, localization, volume estimation, shape reconstruction, and material ranking within a unified analysis pipeline. Simulation studies with multiple objects of different compositions demonstrate accurate reconstruction of object positions and geometries, while providing reliable material discrimination based on scattering density. The developed system offers a scalable approach for next-generation cosmic muon tomography applications in security screening, nuclear waste characterization, and non-destructive inspection.

Explore related subjects

Keep this discovery

BibTeXRIS

Bharat Kumar Sirasva, Rohit Gupta, Satyajit Jena. 2026-08-24. A Cosmic Muon Tomography System with Machine Learning based Momentum Measurement for Multi-Object Reconstruction and Material Characterization. https://arxiv.org/abs/2608.23141

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det