SearcharxivSearch

arXiv · 2608.24917

Cusp-singularity-enhanced Coriolis effect for ultrasensitive chip-scale gyroscopes

Abstract

Gyroscopes, as fundamental inertial sensors, are crucial for rotation measurements in consumer electronics, automotive, and aerospace industries, with the most widely used kind relying on the Coriolis effect. The chip-scale Coriolis vibratory gyroscopes (CVGs) show reduced size, weight, and cost, but remain far lower performance than traditional macroscale CVGs, as the weak intrinsic Coriolis factor sets a fundamental limit on scaling the sensitivity against the inherently louder Brownian noise in microchips compared to the macroscale ones. Here, to overcome this physical limit, for the first time, we propose and experimentally demonstrate the use of third-order singularities lying within cusp catastrophes in the phase-tracked oscillations of an on-chip CVG to facilitate a cubic-root scaling of the Coriolis-effect-induced frequency modulation. Employing this effect, we achieve a three-order-of-magnitude enhancement in the Coriolis factor, yielding a 253-fold improvement in signal-to-noise ratio and a 297-fold increase in precision. Moreover, the cusp singularity enables a previously unattainable ultrasensitive phase-modulated sublinear measurement, achieving a world-record signal-to-noise ratio performance for silicon-chip gyroscopes. These findings not only provide revolutionary advancements in gyroscope technologies, by filling the gap in observing and controlling the singularity-enhanced Coriolis effect, but also shed new light on other ultrasensitive sensing applications.

Explore related subjects

Keep this discovery

BibTeXRIS

Sen Zhang, Dingbang Xiao, Fei Wang, Ran Huang, Lei Yu, Ning Zhou, Kaixuan He, Xuezhong Wu, Franco Nori, Hui Jing, Xin Zhou. 2026-08-11. Cusp-singularity-enhanced Coriolis effect for ultrasensitive chip-scale gyroscopes. https://doi.org/10.1038/s41586-026-10565-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det