Searcharxiv⌕ Search

arXiv · 2610.03178

Residual AM and PM Noise of Selected X-Band Amplifiers

Abstract

In microwave systems design, amplitude modulation (AM) noise is often ignored relative to phase modulation (PM) noise. However, in high-performance applications requiring ultra-low PM noise, AM noise becomes a critical limiting factor due to AM-to-PM conversion mechanisms. Because AM noise specifications are rarely, if ever, provided for commercial microwave components, this study characterizes the residual AM and PM noise of several 10 GHz amplifiers. We present performance data for various Heterojunction Bipolar Transistor (HBT) amplifier designs and demonstrate the noise reduction achieved through power-summed configurations. For example, a discrete-die GaAs HBT amplifier achieves residual PM noise below $-160$ dBrad$^2$/Hz and AM noise of approximately $-155$ dB/Hz at a 1 kHz offset in a quad power-summed configuration. A notable finding is that the majority of amplifier designs surveyed in this study exhibit higher AM noise relative to their PM noise, with only a few exceptions. The impact of bias supply quality on residual noise is also quantified, demonstrating that the choice of voltage regulator is a first-order design parameter below 1 kHz offset.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Archita Hati, Craig Nelson, Scott Littrell. 2026-10-02. Residual AM and PM Noise of Selected X-Band Amplifiers. https://arxiv.org/abs/2610.03178

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of Small-pitch, Ultra-thin 3D Silicon Sensors at USTC

We report on the development of 3D silicon sensors at the University of Science and Technology of China (USTC). The sensor involves columnar electrodes (5 um in diameter) of both doping types, etched from the same wafer side. The p+ electrodes pass through the epitaxial wafer, whereas the n+ electrodes stop at a short distance from the opposite side of the epitaxial wafer. Based on the current processing capacity, the sensors feature an ultra-thin active substrate (50 um) and a small pixel size of 50 um x 50 um or 25 um x 25 um. This R&D project aims to establish a sensor technology to simultaneously measure position and time information at the single-pixel level. The first fabrication run, using a merged layout containing both pixel sizes, has been completed. The design and fabrication of the sensors, followed by their characterization, including Current-Voltage (I-V) measurements and Sr-90 beta source measurements, are reported in this paper.

physics.ins-det↗

MOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectors

The XLZD observatory is a next-generation experiment designed to search for weakly interacting massive particles (WIMPs) and other rare events using a 60-80 tonne liquid xenon time projection chamber (TPC). This detector aims to achieve sensitivity across the full WIMP parameter space down to the neutrino fog, establishing the ultimate sensitivity for this dark matter search paradigm. This unprecedented scale introduces substantial engineering challenges and pushes operation into largely unexplored regimes: the interplay between high-voltage (HV) systems, liquid xenon, and conducting materials in ultra-pure environments. To systematically investigate these challenges, we have built MOTION, a 70 kg LXe detector dedicated to understanding HV performance and electrostatic phenomena up to 200 kV (negative polarity). We describe the design and construction of the experimental infrastructure, including the cryogenic system, xenon purification and storage. MOTION enables controlled studies of dielectric breakdown in LXe, permitting systematic characterization of discharge mechanisms and their dependence on electrode geometry, surface condition, and applied voltage. The detector also facilitates investigations of field emission and photoemission from electrodes following various surface treatments, and provides a platform for validating the design of an HV feedthrough constructed from radiopure materials. The insights from these studies are essential for ensuring the operational stability, radiopurity, and scalability required for next-generation dark matter detectors.

physics.ins-det↗

Controlled-illumination smartphone imaging for quantitative turbidity measurement and cross-device transfer

Smartphone imaging could provide a low-cost turbidity measurement method if illumination and acquisition geometry are controlled. We evaluated a 3D-printed enclosure with fixed illumination and a submerged optical target using 162 milk-based suspensions spanning 0.16--50.2 nephelometric turbidity units (NTU), with a portable turbidimeter as the reference. An EfficientNetB0 regression model evaluated using repeated five-fold grouped cross-validation achieved a mean absolute error (MAE) of 1.208 NTU and $R^2=0.9816$, indicating that predictions followed the reference measurements closely. The MAE was 0.335 NTU below 1 NTU and 0.449 NTU from 1 to below 5 NTU; classification accuracy at the operational 5-NTU threshold was 0.9753. When applied without retraining to 103 paired images from a second smartphone, prediction error remained comparable to that on the development smartphone below 10 NTU, but turbidity was increasingly underestimated at higher values. The results demonstrate the measurement performance attainable with a controlled smartphone acquisition system, quantify an important device-dependent transfer limitation, and motivate standardized multi-device acquisition and prospective natural-water validation.

physics.ins-det↗