Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout

Abstract

Double-sided silicon strip detectors (DSSDs) are widely used for charged-particle detection in nuclear reaction experiments. However, the large number of readout channels associated with DSSDs places stringent demands on front-end electronics and data acquisition systems, particularly in experiments employing large detector arrays. In this work, we investigate the application and optimization of the Generic Electronics for Time Projection Chambers (GET) system for multi-channel DSSD readout. Through optimization of the DC-blocking capacitors on the custom-designed interface board and waveform-based energy extraction algorithms, the readout system achieves an energy resolution of σ = 22 keV for 5.49 MeV alpha particles. Its performance is further validated in a representative nuclear physics experiment employing charged-particle telescopes. The results demonstrate that the GET system provides a versatile and scalable waveform-sampling solution for multi-channel DSSD readout.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jiawei Bian, Zaihong Yang, Qite Li, Zeyu Du, Xuan Wang, Ningtao Zhang, Pengjie Li, Zhongtao Shen, Kaijie Zhou, Cheng Wang. 2026-10-09. Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout. https://doi.org/10.1016/j.nima.2026.171772

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The throttling refrigeration system for high cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal

The PandaX-xT cryogenic distillation system for removing radon (Rn) is designed to operate at a high liquid flow rate of 856 kg/h, equal to 5 liters per minute (LPM), to meet the required Rn concentration. However, it is challenging to maintain a continuous supply of cooling power (20 kW) for the Rn-removal system. This work proposes a throttling refrigeration system to address the power supply problem for the next-generation PandaX-xT dark matter detection experiment. The system utilizes carbon tetrafluoride (R14) refrigerant to recover power based on heat pump principles. The cooling power from the liquid xenon (LXe) in the reboiler at 178 K is transferred to liquefy the gaseous xenon (GXe) in the cryostat through the phase change circulation of R14, enabling xenon (Xe) to return to the detector in the same state as when it was extracted. Consequently, a stable circulation for liquid distillation is established. Given the high cost of Xe, a research and development (R&D) experiment has been conducted to validate the feasibility of this high-cooling-recovery system by using ethanol as a substitute for Xe. Experimental results indicate that the proposed system could achieve a cooling power recovery of 25 kW, with a recovery efficiency of 99%+-0.5%. Additionally, process simulation and optimization of the throttling refrigeration cycle are performed using Aspen Hysys. The deviation between the simulation and experimental results is found to be <3.64%. These findings demonstrate that implementing Rn-removal distillation at a high flow rate is feasible, eliminating the need for liquid nitrogen or cryocoolers. This system could save approximately 3650 m3 of liquid nitrogen per year or reduce power consumption by 230 kW.

physics.ins-det↗

CNN-based Position Reconstruction for the T0 Detector in the HIRFL-CSR External-target Experiment

The T0 detector provides the event start time for the HIRFL-CSR external-target experiment, and its multi-channel readout signals also contain 2D position information of incident particles. In the CEE experiment, the dedicated beam-profile detector has a rate capability of only ~1 kHz, far below the beam event rate of up to 1 MHz, so it cannot provide real-time beam-spot monitoring under high-rate data-taking or an event time reference. To fill this gap, this work studies a CNN-based position reconstruction method that enables the T0 detector to provide both start time and beam-spot information. The over-threshold times and time-over-threshold (TOT) values from 32 SiPM channels are reorganized into a geometry-preserving input tensor. Time features are corrected by event-wise mean-time subtraction, and TOT features are normalized by an event-wise trimmed mean before feature standardization. A customized CNN directly regresses the incident coordinates. Training and validation samples are built with Geant4 simulation and waveform digitization, and the method is evaluated using a pulsed-laser scanning data set with known position labels. On independent test sets, the residual standard deviations for uniformly distributed planar simulation data are about 1.11 and 1.04 mm in x and y. For the discrete laser-scanning geometry, the resolutions are about 2.36 and 1.34 mm in simulation and 2.42 and 1.41 mm in experiment. The trained model is applied to CEE zero-field beam data collected at the Institute of Modern Physics, Lanzhou, in January 2026, and a 2D beam-spot distribution is reconstructed. These results show the T0 detector's potential as a high-rate beam-spot monitor while retaining its role as an event start-time detector.

physics.ins-det↗

Beam Spill Structure Measurements at CEE Using the T0 Detector

The Cooling Storage Ring External-target Experiment (CEE) at the Heavy Ion Research Facility in Lanzhou uses a slow-extracted heavy-ion beam whose temporal profile directly affects detector occupancy. The existing CEE T0 detector, originally designed to provide the event start time, is extended in this work to measure the spill structure immediately upstream of the fixed target. The detector consists of a 0.8-mm-thick EJ-200 plastic scintillator read out by 16 silicon photomultipliers at each end. The SiPM signals are conditioned and discriminated by the NINO front-end electronics, and the resulting timing signals are recorded using an FPGA-based time-to-digital converter. In laboratory tests, with the laser trigger set to its maximum available repetition frequency of 100~MHz, the recorded T0 hit-rate distribution was concentrated around 100~MHz. During the June 2024 beam test with 350-MeV/u Kr ions, the accelerator team varied several operating settings, including RF-KO, sextupole, and feedback settings, while T0 independently recorded the corresponding spill profiles. An empirical representation was used to extract the rise, plateau, and fall durations from the stored profiles. The plateau duration was used as the primary comparison metric while accelerator stability and RF-system load were also considered. The measurements clearly distinguished the spill-profile responses associated with different accelerator settings. The spill obtained with the selected settings exhibited a more nearly rectangular envelope than the initial profile, although residual fluctuations and a terminal spike remained. These results demonstrate that the existing CEE T0 detector can provide independent beam-structure information during accelerator tuning.

physics.ins-det↗