SearcharxivSearch

arXiv · 2512.20947

The throttling refrigeration system for the large cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal

Abstract

In order to solve the continuous large cooling power supply problem (20 kW) for the radon-removal cryogenic distillation system, which operates at high liquid ffow rate of 856 kg/h (5 LPM) for the dark matter detector PandaX-xT of the next-generation, a throttling refrigeration system based on carbon tetraffuoride (R14) refrigerant for cooling power recovery is designed and developed. According to this system, the cooling power of the liquid xenon in the reboiler of 178K could be transferred to the product xenon cryostat to liquefy the gaseous product xenon by the R14 circulation, thus the liqueffed xenon could return to the detector with the same condition of which extracted from the detector to form a stable cooling cycle and prevent the instability of the detector. A research and development experiment is implemented to validate the feasibility of this large cooling recovery system, using the ethanol to simulate the liquid xenon. Experimental results show that the cooling power recovery of this system could achieve 17 kW with the efffciency of 76.5%, and the R14 ffow rate is 0.16 kg/s. This study realizes the online radon removal distillation with large ffow rate while eliminating the dependence of liquid nitrogen or cryocoolers, which means saving 2414 m3 liquid nitrogen per year or the power consumption of 230 kW. Furthermore, process simulation and optimization of the throttling refrigeration cycle is studied using Aspen Hysys to reveal the inffuences of the key parameters to the system, and the deviation between the simulation and experimental results is < 2.52%.

Explore related subjects

Keep this discovery

BibTeXRIS

Shunyu Yao, Zhou Wang, Kangkang Zhao, Zhi Zheng, Haoyu Wang, Xiangyi Cui, Tao Zhang, Li Zhao, Huaikuang Ding, Wenbing Tao, Xiang Xiao, Shaobo Wang, Yonglin Ju, Jianglai Liu, Xiangdong Ji, Shuaijie Li, Manbin Shen, Chengbo Du. 2025-12-24. The throttling refrigeration system for the large cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal. https://arxiv.org/abs/2512.20947

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det