Searcharxiv⌕ Search

arXiv · 2610.16515

Readout chain of SPD DAQ system

Abstract

The Spin Physics Detector (SPD) experiment at the NICA collider of the Joint Institute for Nuclear Research (JINR) aims to study the spin structure of the nucleon and spin-related phenomena. The experimental conditions, including the high interaction rate and the large number of readout channels, require a triggerless data acquisition system with high throughput and a scalable architecture. This work presents a hardware implementation of the readout chain that extends the previously proposed SPD DAQ architecture. The chain is based on two levels of concentrators. The L1 concentrator provides the interface between the front-end electronics and the next system level and distributes synchronous signals. The L2 concentrator aggregates data streams from several L1 concentrators before transmitting them to the computing system. A key feature of the L2 implementation is the offloading of data reception, buffering, and aggregation from the host CPU to the FPGA, motivated by the large number of small packets generated by the readout electronics. The developed hardware platforms and their operating logic are presented, together with experimental results for the main interfaces and data-path components. The obtained results demonstrate the feasibility of the proposed hardware architecture and its application in a scalable SPD data acquisition system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L. Afanasyev, A. Berngardt, A. Boikov, V. Borshch, D. Erofeev, V. Frolov, K. Gritsay, V. Olshevsky, A. Kulikov, S. Tereshchenko, V. Tereshchenko. 2026-10-12. Readout chain of SPD DAQ system. https://arxiv.org/abs/2610.16515

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Physics at the Edge: Benchmarking Quantisation Techniques and the Edge TPU for Neutrino Interaction Recognition

This work presents a benchmark of quantisation techniques for convolutional neural networks applied to neutrino interaction recognition, motivated by the need for low-power inference close to the detector in future liquid argon time-projection chamber (LArTPC) experiments. Using simulation of a generic LArTPC, four Keras models are trained to classify neutral-current, muon-neutrino charged-current and electron-neutrino charged-current interactions, quantised using post-training integer quantisation and quantisation-aware training, and deployed on the Google Coral Edge TPU. Latency and energy per event are compared with those of an Intel Core i7-13650HX CPU, a consumer NVIDIA RTX 4060 GPU and a data-centre NVIDIA A100 GPU, using measured energy at different batch sizes and thread counts; the energy of the Edge TPU is estimated from its nominal power. The accuracy degradation is strongly model-dependent: InceptionV3 shows no significant loss along either pipeline, whereas the other models are substantially degraded. At batch size 1, the Edge TPU is comparable to or faster than the CPU and 1.3-6.5 times slower than the A100, while requiring 5--70 times less energy per event than the other devices; with batching, the GPUs reduce this gap to a factor of 2.6-7.2. The Edge TPU is also approximately four times cheaper than the consumer GPU and more than two orders of magnitude cheaper than the A100. Its low power per device eases deployment where power and cooling are constrained, with an additional benefit in terms of environmental impact. This paper explores possible future integrations of edge AI technologies with neutrino physics.

physics.ins-det↗

Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM

Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.

physics.ins-det↗

Development of high-resolution timing technique in the past 25 years

This paper reviews recent progress in high-resolution timing, rate capability, and aging performance of particle detectors in the context of developments over the past 25 years. It focuses on MCP, SiPM, LGAD, 3D silicon, and SiEM detectors and compares their performance with that of gaseous timing detectors. In addition, preliminary results from a simplified simulation program, Mini-TCAD, are presented, indicating that hexagonal 3D silicon cells may provide better drift-time uniformity and timing resolution than square cells.

physics.ins-det↗