A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring

Abstract

Proton therapy enables highly conformal tumour irradiation by exploiting the Bragg peak. Clinical precision relies on detector systems that provide linearity, spatial resolution, radiation hardness, and, for ultra-high-dose-rate (FLASH) therapy, high dynamic range with sufficient temporal response. No compact all-in-one solution currently fulfils all these requirements. Here, we present pixelated gallium nitride (GaN) arrays as a multifunctional platform. These detectors exhibit high linearity (proton currents from 70 to 1700 pA cm-2) and signal uniformity below 2% across 128 pixels. To probe GaN radiation hardness, we applied cumulative doses up to 6.7 MGy at energies from 25 MeV down to the Bragg-peak regime. Locally deposited dose dictates long-term signal loss, yet devices preserve linearity and spatial response. We demonstrate 0.25 mm effective spatial resolution, validated against radiochromic film. Proton radiography resolves fine tissue structures, with the dose extrapolated to 7 mGy per 1 ms frame in a prospective single-shot configuration. Energy-dependent responses match GATE/Geant4 simulations, and wedge measurements enable Bragg-peak tracking with an energy resolution below 10 keV in an optimised geometry. Real-time ms-scale beam monitoring enables live dose verification.These results establish GaN pixel detectors as a scalable and radiation-hard platform, enabling dosimetry, beam monitoring and energy verification in one device.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nico Frederic Brosda, Stephane Higueret, Nicolas Arbor, Matilde Siviero, Maxime Hugues, Eric Frayssinet, Luisa Parschat, Christian Baumer, Andreas Dirk Wieck, Jean Yves Duboz. 2026-10-14. A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring. https://arxiv.org/abs/2610.20304

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Photoacoustic imaging of human brain function through intact adult skulls

Blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) has revolutionized noninvasive imaging of human brain function, but it indirectly senses deoxyhemoglobin through water-proton relaxation and relies on bulky, costly, noisy, enclosed, superconducting-magnet scanners. In contrast, photoacoustic computed tomography (PACT) directly probes hemoglobin absorption using a more compact, lower-cost, quieter, open, magnet-free system. However, functional PACT of the adult human brain has so far been demonstrated only after surgical skull removal, because the skull strongly attenuates optical and acoustic signals. Here, we demonstrate non-invasive transcranial functional PACT (T-fPACT) through the intact adult skull. A densely packed, high-channel-count (3,072-element) hemispherical ultrasonic array provides near-$2π$-steradian simultaneous acquisition, enabling high sensitivity and single-shot three-dimensional imaging at 20 Hz that eliminates motion blurring. Participant-specific stabilization further enables measurement of small task-evoked hemodynamic responses over the entire task duration. In healthy adults, T-fPACT localized responses to expected sensorimotor regions, distinguished task-specific motor representations, and yielded consistent localizations across repeated task runs and visits. Comparison with high-field (7 T) fMRI showed spatially corresponding functional regions, while dual-wavelength imaging revealed distinct hemoglobin-weighted responses. These findings overcome the long-standing skull barrier in human brain PACT and establish non-invasive, rapid volumetric photoacoustic imaging of brain function.

physics.med-ph↗

Direct correlation of intravoxel incoherent motion imaging based on implicit neural representations and histopathology in pediatric Wilms tumors: can it differentiate between subtypes?

Wilms tumor (WT) is a heterogeneous pediatric renal malignancy. Invasive procedures to establish histology prior to pre operative treatment are not recommended by the International Society of Pediatric (SIOP) Oncology Renal Tumor Study Group, yet different tissue components are associated with different responses to therapy (SIOP Umbrella protocol). Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) may improve subtype differentiation before surgery as a noninvasive radiographic biomarker by capturing both diffusion and perfusion characteristics, as opposed to the conventionally used apparent diffusion coefficient (ADC). The objective of this study is to evaluate the discriminative performance of IVIM MRI in differentiating WT subtypes. IVIM provides quantitative parameters that disentangle the diffusion coefficient (D), incoherent blood flow (pseudodiffusion Dstar) and perfusion fraction (f). This retrospective study included thirthy children with WT. Standardized 1.5T MRI with 10 b value diffusion weighted imaging (DWI) was performed. IVIM parameters were estimated using a selfsupervised implicit neural representations network and were correlated with histopathology via a patient specific 3D printed cutting guide. Statistical analyses included mixed models, receiver operating curve analysis, and logistic regression. Thirty lesions were MRI histopathology correlated on slice level. Significant subtype differences were observed for Dstar stromal versus epithelial (p = 0.024), regressive tumors (p = 0.031) and mixed WT tumors (p = 0.043). ADC showed no significant subtype differences. Direct MRI histopathology correlation enabled differentiation between stromal subtype and epithelial, mixed and regressive subtype on macroscopic slice level using Dstar.

physics.med-ph↗

Can $^{225}$Ac be imaged on a long axial field-of-view PET/CT with standard clinical settings?

Purpose: The $^{225}$Ac decay chain includes $^{209}$Tl, whose prominent 1567 keV gamma line can create electron-positron pairs. We investigated whether a long axial field-of-view (LAFOV) PET/CT can image $^{225}$Ac using standard clinical acquisition and reconstruction methods. Methods: A syringe placed next to a vial (5.89 and 10.29 MBq of $^{225}$Ac activity) and a NEMA IEC body phantom (sphere activity concentration 4.56 kBq mL$^{-1}$) were scanned for 45 and 60 min, respectively, on a Biograph Vision Quadra (Siemens Healthineers). To support our findings, FLUKA simulations scored the annihilation locations around a $^{225}$Ac point source. Results: The contours of the syringe and vial were visible despite high noise, but the NEMA spheres could not be distinguished from the background. As illustrated by the FLUKA simulations, the number of annihilation events decreases exponentially according to the mean free path of the 1567 keV photon in the surrounding medium. Conclusion: A LAFOV PET/CT can detect positrons created by pair production of the main $^{209}$Tl gamma line. However, these positrons are created where the photons interact with the surrounding medium rather than at the location of the $^{209}$Tl decays, which rules out standard PET imaging of $^{225}$Ac.

physics.med-ph↗