Searcharxiv⌕ Search

arXiv · 2611.20211

Detection of minimum ionising particles with internal gain in the first Silicon Electron Multiplier demonstrators

Abstract

The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionising particle (MIP) detection that uses internal gain achieved through a composite electrode structure embedded within the silicon bulk. Unlike conventional gain sensors (LGADs, APDs), the SiEM achieves amplification through applied electric potentials rather than doped gain layers, potentially offering superior radiation hardness above $10^{16}\,n_{\mathrm{eq}}/\mathrm{cm}^2$. Following initial conceptual studies and simulation work, several fabrication approaches were explored, including Deep Reactive Ion Etching (DRIE) at Centro Nacional de Microelectrónica (CNM) and Metal Assisted Chemical Etching (MACEtch) at the Paul Scherrer Institute (PSI). This paper reports the first experimental results from functional SiEM demonstrators produced by Hamamatsu Photonics K. K. (HPK) using a single-electrode configuration with modified geometry. Electrical characterisation through I-V measurements and test beam studies with minimum ionising particles demonstrate clear evidence of charge multiplication, with gains comparable to simulation predictions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Federico De Benedetti, Sara Cesare, Victor Coco, Paula Collins, Raphael Dumps, Edgar Cid Lemos, Samuel Mico, Janina Nicolini, Alfonso Puicercus Gomez, Efren Rodriguez Rodriguez, Lotte Sikkema, Hironori Sonobe, Abraham Gallas Torreira, Morag Williams. 2026-11-15. Detection of minimum ionising particles with internal gain in the first Silicon Electron Multiplier demonstrators. https://searcharxiv.com/abs/2611.20211

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗