Searcharxiv⌕ Search

arXiv · 2611.20343

Advancing Electroformed X-ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy: Improved Figure Accuracy and X-ray Imaging Performancev

Abstract

We have developed high-resolution electroformed nickel X-ray telescope mirrors by extending precision mirror-fabrication techniques developed for synchrotron X-ray microscopy to space astronomy. Our previous study identified axial figure errors of a replicated mirror as one of the factors limiting its X-ray angular resolution. In the present study, we fabricated a new mirror using a substantially improved mandrel and directly compared the two-dimensional figure errors of the mandrels and replicated inner mirror surfaces for both the previous and new mandrel--mirror pairs. This comparison reveals how contributions to the final mirror figure errors changed with improved mandrel accuracy. For the previous mirror, the mandrel and mirror showed a strong spatial correlation in their figure errors, indicating that a substantial component of the mirror figure pattern was inherited from the mandrel. In contrast, after improving the mandrel figure, the new mirror exhibited a weaker mandrel--mirror spatial correlation, while the residual figure deviations arising between the mandrel and final mirror became comparable in magnitude to the residual mandrel figure errors. The improved mandrel reduced the central 68% widths, W68, of the axial slope error distribution from 3.3 to 1.6 arcsec for the paraboloidal surface and from 5.0 to 1.1 arcsec for the hyperboloidal surface. Correspondingly, the mirror values improved from 4.6 to 2.4 arcsec and from 12.4 to 2.0 arcsec, respectively. X-ray measurements at 12 keV yielded local half power diameters (HPDs) of approximately 7--17 arcsec and a full-aperture HPD of 8.5 arcsec. The newly fabricated mirror was adopted for the soft X-ray telescope of the fifth Focusing Optics X-ray Solar Imager (FOXSI-5) sounding rocket flight and was successfully flown in May 2026.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ikuyuki Mitsuishi, Yusuke Yoshida, Kazuki Ampuku, Makoto Yoshihara, Keitoku Yoshihira, Tetsuo Kano, Naoki Ishida, Koki Sakuta, Noriyuki Narukage, Keisuke Tamura, Kikuko Miyata, Gota Yamaguchi, Hidekazu Takano, Yoshiki Kohmura, Shutaro Mohri, Takehiro Kume, Yusuke Matsuzawa, Yoichi Imamura, Takahiro Saito, Kentaro Hiraguri, Hirokazu Hashizume, Hidekazu Mimura. 2026-11-16. Advancing Electroformed X-ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy: Improved Figure Accuracy and X-ray Imaging Performancev. https://searcharxiv.com/abs/2611.20343

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Optimal robust detection statistics for pulsar timing arrays

Pulsar timing arrays (PTAs) seek to detect a nano-Hz stochastic gravitational-wave background (GWB) by searching for the characteristic Hellings and Downs angular pattern of timing residual correlations. So far, the evidence remains below the conventional $5σ$ threshold, as assessed using the literature-standard "optimal cross-correlation detection statistic". While this quadratic combination of cross-correlated data maximizes the deflection (signal-to-noise ratio), it does not maximize the detection probability at fixed false-alarm probability (FAP), and therefore is not Neyman-Pearson (NP) optimal for the assumed noise and signal models. The NP-optimal detection statistic is a different quadratic form, but is not used because it also incorporates autocorrelations, making it more susceptible to uncertainties in the modeling of pulsar timing noise. Here, we derive the best compromise: a quadratic detection statistic which is as close as possible to the NP-optimal detection statistic (minimizing the variance of its difference with the NP statistic) subject to the constraint that it only uses cross-correlations, so that it is less affected by pulsar noise modeling errors. We study the performance of this new NPMV statistic for a simulated PTA whose noise and (putative) signal match those of the NANOGrav 15-year data release: GWB amplitude $A_{\rm gw} = 2.1 \times 10^{-15}$ and spectral index $γ= 13/3$. Compared to the literature-standard "optimal" cross-correlation detection statistic, the NPMV statistic increases the detection probability by 47% when operating at a $5σ$ false-alarm probability of $α= 2.9 \times 10^{-7}$.

astro-ph.IM↗

Wideband overlapped polyphase channelizer for kinetic inductance detector readout: split-path architecture and experimental characterization

Frequency-multiplexed readout of kinetic inductance detector arrays measures the complex transmission of thousands of superconducting resonators. The channelizer that separates them introduces systematic effects: a gain that depends on where each tone falls in the channel grid, leakage between channels and added noise. This article presents a 4096-channel polyphase channelizer with 2/1 overlap for a 4.096 GS/s input, implemented on a first-generation radio-frequency system-on-chip, and a procedure to characterize it on the board with two receive chains, one digitizing the excitation as a reference. A split-path architecture computes the two overlap states in parallel filter branches at 256 MHz and reorders them frame by frame, under three control rules; it keeps only the transform stage at 512 MHz and affords a prototype of 16 taps per polyphase path (65536 coefficients) at the multiplication rate of a published 8-tap bank. Each selected channel is exported as a complex series at 1 MS/s. The measured channel response follows the coefficient-table model within 0.15 dB down to -28 dB, with both overlapping channels at full gain across their common band. Leakage into every measured channel 1.875 MHz or more from the tone is -94 dBc or lower, apart from images attributed to converter interleaving. The signal-to-noise ratio per sample lies within 1.7 dB of the limit set by the data-sheet noise density of the converter, and an emulated detector pulse is recovered with a decay time of 14.65 $μ$s (standard uncertainty 0.04 $μ$s), within 0.7% of the expected value.

astro-ph.IM↗

Improved compensation for missing high-order aberrations with multi-frame blind deconvolution and phase diversity techniques

Context. Image restoration with phase diversity (PD) and multi-frame blind deconvolution (MFBD) techniques lead to remarkable improvement in image quality, but is limited by the number of aberration parameters that can be determined. Compensation for the missing high-order modes is needed to further improve image quality, and to compensate for residual straylight. Aims. We aim to improve on methods for compensating missing high-order aberrations previously proposed by Scharmer et al. (2010) and Lofdahl & Hillberg (2022). Methods. The wavefront is divided into a set of low-order aberrations, which are treated individually, and high-order aberrations that are treated collectively. The high-order part of the transfer function is averaged, assuming Gaussian seeing statistics with Kolmogorov turbulence for the individual aberrations. Assuming that their accumulated effect is roughly uniform over the pupil, we obtain a high-order modulation transfer function that is represented with a single free parameter. Results. The high quality of the of the proposed high-order modulation transfer function is verified by calculating the Strehl from random samples of point-spread functions for D/r0 ranging from 4 to 20, where D is the telescope diameter and r0 the Fried seeing parameter. The proposed approximation offers significant advantages over the earlier proposals. Conclusions. The proposed method of compensating for missing high-order aberrations in PD or MFBD image reconstruction can dramatically improve the fidelity of solar images. Variations of the seeing (r0) within a data-set can be compensated for self consistently during PD or MFBD processing, but the average value of r0 must be provided from an external source. The computational cost of implementing this method is marginal.

astro-ph.IM↗