SearcharxivSearch

arXiv · nucl-ex/0608027

In Beam Tests of Implanted Helium Targets

Abstract

Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The implanted targets were bombarded with moderately intense 4He and 16O beams of 50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams and recoil helium from 15.0 MeV oxygen beams were used to study the helium content and profile before, during and after bombardments. We observed the helium content and profile to be very stable even after a prolonged bombardment (up to two days) with moderately intense beams of 16O or 4He. Helium implanted into thin (aluminum) foils is a good choice for thin helium targets needed, for example, for a measurement of the 3he(a,g)7Be reaction and the associated S34 astrophysical cross section factor (S-factor).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. E. McDonald, R. H. France III, R. A. Jarvis, M. W. Ahmed, M. A. Blackston, Th. Delbar, M. Gai, T. J. Kading, Y. Parpottas, B. A. Perdue, R. M. Prior, D. A. Rubin, M. C. Spraker, J. D. Yeomans, L. Weissman, H. R. Weller, E. L. Wilds Jr, ;, UHartford, GCSU, LNS/UConn, TUNL/Duke, UCL/LLN, Yale, NGCSU. 2006-08-16. In Beam Tests of Implanted Helium Targets. https://doi.org/10.1088/1748-0221%2F1%2F09%2Fp09003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Reinvestigation of the Yield of the Trinity Device

Previous published analyses of trinitite to determine the yield of the Trinity nuclear explosion used various estimates of the fraction of fission products that became incorporated in trinitite. Furthermore, these studies utilized nuclear data that has subsequently been revised. Utilizing a planar germanium detector, we observed gamma rays produced by the decays of both 137Cs and 239Pu from four samples of trinitite. From the observed 137Cs/239Pu ratios of and a simple analysis method based on current nuclear data and weapons debris studies, we find an average yield of 9.1+-4.5 kilotons from our four samples. While this result is substantially lower than the established total yield of 21 kilotons, it is in reasonable agreement that attributable to fissions in the 239Pu core alone.

nucl-ex

Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements

Mass measurements of the ground and isomeric states of $^{68-70}$Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were measured, either for the first time for the isomeric states of $^{68}$Co and $^{70}$Co, or with greatly improved precision for the others, removing ambiguities in the mass surface beyond $N=40$. The ordering of the low and high-spin states in $^{68}$Co and $^{70}$Co has also been established. The results, supported by Large-Scale Shell Model and Discrete Non-Orthogonal Shell-Model calculations, show a gradual lowering of intruder states with increasing neutron number, eventually leading to an inversion in $^{70}$Co. These findings clarify previously proposed contradictory interpretations. Finally, we demonstrate the importance of including induced effective 3N forces for a consistent description of binding energies in the island of inversion near $N=40$.

nucl-ex