arXiv · physics/0012046
Measurements of Spatial Resolution of ATLAS Pixel Detectors
Abstract
Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.
Explore related subjects
Keep this discovery
T. Lari. 2000-12-19. Measurements of Spatial Resolution of ATLAS Pixel Detectors. https://doi.org/10.1016/s0168-9002(01)00365-5
Cite the original work for its findings. Save a collection to share your selection of sources.