Indoor radon (Rn-222) concentration measurements in Cyprus using high-sensitivity portable detectors
Abstract
Using high--sensitivity radon (Rn-222) portable detectors (passive electronic devices of the type RADIM3), the airborne Rn-222 concentration in the interior of various Cypriot buildings and dwellings was measured. For each preselected building and dwelling, a calibrated detector was put into a closed room, and the Rn-222 concentration was registered in sampling intervals of 2 to 4 hours for a total counting time of typically 48 hours. Rn-222 activity concentrations were found to be in the range of 6.2 to 102.8 Bq/m**3, with an overall arithmetic mean value of (19.3 +- 14.7) Bq/m**3. This value is by a factor of two below the world average (population-weighted) value of 39 Bq/m**3. The total annual effective dose equivalent to the Cypriot population was calculated to be between 0.16 and 2.6 mSv with an overall arithmetic mean value of (0.49 +- 0.37) mSv.
Explore related subjects
Keep this discovery
T. Anastasiou, H. Tsertos, S. Christofides, G. Christodoulides. 2003-02-04. Indoor radon (Rn-222) concentration measurements in Cyprus using high-sensitivity portable detectors. https://arxiv.org/abs/physics/0212105
Cite the original work for its findings. Save a collection to share your selection of sources.