SearcharxivSearch

arXiv subjects

A. Pazos

Publications and source records attributed to A. Pazos.

At least 19 recordsLinked to original sources

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

physics.ins-det

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal \Rn{222} activity is found to be (0.95$\pm$0.04(stat)$\pm$0.09(sys)) Bq/m$^3$, while no traces of \Rn{220} have been observed. Most of the \Rn{222} progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced \Bi{214} of (0.97$\pm$0.05(stat)$\pm$0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the \bbnonu region of interest is evaluated as (7.3$\pm$1.5(stat)$\pm$0.8(sys))$\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) after selection of the fully contained events. This background index is reduced to $\sim$4$\times10^{-5}$ counts/(keV$\cdot$kg$\cdot$yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

hep-ex

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

physics.ins-det

A journey to ITACA: Ion Tracking with Ammonium Cations Apparatus

A unique feature of gas xenon electroluminescent time projection chambers (GXeEL TPCs) in $0\nu\beta\beta$ searches is their ability to reconstruct event topology, in particular to distinguish "single-electron" from "double-electron" tracks, the latter being the signature of a $0\nu\beta\beta$ decay near the decay endpoint $Q_{\beta\beta}$. Together with excellent energy resolution and the t$_0$ provided by primary scintillation, this topological information is key to suppressing backgrounds. Preserving EL, however, requires operation in pure xenon (with helium as the only benign additive), where electron diffusion is large. Consequently, reconstructed track fidelity is limited by diffusion and intrinsic EL blurring. We propose augmenting the detector with the ability to image not only the electron track but also the corresponding mirror ion track. Introducing trace amounts of NH$_3$ ($\sim$100 ppb) converts primary xenon ions into ammonium ions, NH$_4^+$, via a fast two-step ion-molecule process involving charge transfer followed by proton transfer, while leaving EL unaffected. Electrons drift rapidly to the anode, producing the standard EL image, whereas NH$_4^+$ ions drift slowly toward the cathode, allowing time to determine the event energy and barycenter. For events in the region of interest, an ion sensor near the cathode at the projected barycenter captures the ions. Laser interrogation of the sensor's molecular layer then reveals an ion-track image with sub-millimeter diffusion and no EL-induced smearing. Combined electron-ion imaging strengthens topological discrimination, improving background rejection by about an order of magnitude and significantly extending the discovery potential of GXeEL TPCs for very long $0\nu\beta\beta$ lifetimes.

physics.ins-det

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($\beta\beta 0\nu$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{\beta\beta}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{\beta\beta})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $\beta\beta 0\nu$.

physics.ins-det

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $^{136}$Xe using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterr\'aneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83m}$Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83m}$Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta\beta}$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

hep-ex

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of $^{136}$Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ($\leq 1\%$ FWHM at the $Q_{\beta\beta}$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterr\'aneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $\sim$4 bar and drift fields of 74 V/cm and 118 V/cm, respectively. Alpha decays from the $^{222}$Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

physics.ins-det

High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay $0\nu\beta\beta$. The feedthrough has been demonstrated to hold pressures up to 20~bar and sustain voltages as high as -65~kV, and the TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses.

physics.ins-det

Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47+/-0.02 and 181.39+/-0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

physics.ins-det

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle $\cos\theta$ among the two decay electrons, and the electron energy spectra, $T_1$ and $T_2$. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{\cos\theta}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

hep-ex

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.

hep-ex

Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe

The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.

physics.ins-det

TRAGALDABAS. First results on cosmic ray studies and their relation with the solar activity, the Earth magnetic field and the atmospheric properties

Cosmic rays originating from extraterrestrial sources are permanently arriving at Earth atmosphere, where they produce up to billions of secondary particles. The analysis of the secondary particles reaching to the surface of the Earth may provide a very valuable information about the Sun activity, changes in the geomagnetic field and the atmosphere, among others. In this article, we present the first preliminary results of the analysis of the cosmic rays measured with a high resolution tracking detector, TRAGALDABAS, located at the Univ. of Santiago de Compostela, in Spain.

astro-ph.HE

Determination of $ππ$ scattering lengths from measurement of $π^+π^-$ atom lifetime

The DIRAC experiment at CERN has achieved a sizeable production of $π^+π^-$ atoms and has significantly improved the precision on its lifetime determination. From a sample of 21227 atomic pairs, a 4% measurement of the S-wave $ππ$ scattering length difference $|a_0-a_2| = (.0.2533^{+0.0080}_{-0.0078}|_\mathrm{stat}.{}^{+0.0078}_{-0.0073}|_\mathrm{syst})M_{π^+}^{-1}$ has been attained, providing an important test of Chiral Perturbation Theory.

hep-ex

Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap of 0.5 mm. The small pixel size makes the detector ideal for high gradient beam profiles like those present in Intensity Modulated Radiation Therapy (IMRT) and radiosurgery. As read-out electronics we use the X-Ray Data Acquisition System (XDAS) with the Xchip developed by the CCLRC. Studies concerning the collection efficiency dependence on the polarization voltage and on the dose rate have been made in order to optimize the device operation. In the first tests we have studied dose rate and energy dependences, and signal reproducibility. Dose rate dependence was found lower than 2.5 % up to 5 Gy min$^{-1}$, and energy dependence lower than 2.1 % up to 20 cm depth in solid water. Output factors and penumbras for several rectangular fields have been measured with the linear array and were compared with the results obtained with a 0.125 cm$^{3}$ air ionization chamber and radiographic film, respectively. Finally, we have acquired profiles for an IMRT field and for a virtual wedge. These profiles have also been compared with radiographic film measurements. All the comparisons show a good correspondence. Signal reproducibility was within a 2% during the test period (around three months). The device has proved its capability to verify on-line therapy beams with good spatial resolution and signal to noise ratio.

physics.med-ph

Free ion yield observed in liquid isooctane irradiated by gamma rays. Comparison with the Onsager theory

We have analyzed data on the free ion yield observed in liquid isooctane irradiated by Co60 gamma rays within the framework of the Onsager theory about initial recombination. Several distribution functions describing the electron thermalization distance have been used and compared with the experimental results: a delta function, a Gaussian type function and an exponential function. A linear dependence between free ion yield and external electric field has been found at low electric field values (E<1.2 MV/m) in excellent agreement with the Onsager theory. At higher electric field values we obtain a solution in power series of the external field using the Onsager theory.

physics.ins-det

A two dimensional position sensitive gas chamber with scanned charge transfer readout

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge transfer technique. It has been implemented by using gate strips perpendicularly oriented to the collector strips. This solution reduces considerably the number of electronic readout channels needed to cover large detector areas. The use of a 25 micron thick kapton etched circuit allows high charge transfer efficiency with a low gating voltage, consequently needing a very simple commutating circuit. The present prototype covers 8 x 8 cm^2 with a pixel size of 1.27 x 1.27 mm^2. Depending on the intended use and beam characteristics a smaller effective pixel is feasible and larger active areas are possible. This detector can be used for X-ray or other continuous beam intensity profile monitoring.

physics.ins-det

The Micro Wire Detector

We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 micron apertures, crossed by 25 micron anode strips to which it is attached by 50 micron kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture like in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material.

hep-ex