Searcharxiv⌕ Search

arXiv subjects

Carlo Paolo Sasso

Publications and source records attributed to Carlo Paolo Sasso.

9 recordsLinked to original sources

A Six-Quadrupole Diamagnetic Suspension Architecture for Ultra-Sensitive Space Accelerometry

This paper proposes a novel inertial sensor based on a solid diamagnetic cubic test mass passively suspended by a symmetric configuration of six magnetic quadrupoles. Designed specifically for microgravity environments, this system eliminates the mechanical noise and hysteresis inherent in elastic suspensions, as well as the complexity associated with electrostatic suspension systems. We provide an analysis of the magnetic intrinsic noise floor imposed by eddy current damping, alongside ground-based preliminary experimental results demonstrating potential sensitivities in the order of the $10^{-10} \text{ m/s}^2/\sqrt{\text{Hz}}$ regime.

physics.ins-det↗

Three-dimensional model of a split-crystal x-ray and neutron interferometer

The observation of neutron interference by using a crystal interferometer having a separate analyser opens the way to the construction and operation of interferometers with vast arm separation and length. Setting the design specifications requires a three-dimensional dynamical-theory model of their operation. In this paper, we develop the needed three-dimensional mathematical framework, which also comprises coherent and incoherent illuminations, and apply it to study the visibility of the interference fringes.

physics.ins-det↗

Progress on the Astrometric Gravitation Probe design

The Astrometric Gravitation Probe mission is a modern version of the 1919 Dyson-Eddington-Davidson experiment, based on a space-borne telescope with a permanent built-in eclipse, provided by a coronagraphic system. The expected improvement on experimental bounds to General Relativity and competing gravitation theories is by at least two orders of magnitude. The measurement principle is reviewed, in particular the principle of Fizeau-like combination of a set of individual inverted coronagraphs simultaneously feeding a common high resolution telescope. Also, the payload has a dual field of view property, in order to support simultaneous observations of stellar fields either very close, or far away, from the Sun, i.e. fields affected by either high or low light bending. We discuss a set of solutions introduced in the optical design to improve on technical feasibility and robustness of the optical performance against perturbations, in particular induced by manufacturing and alignment tolerances, and launch stresses.

astro-ph.IM↗

A more accurate measurement of the $^{28}$Si lattice parameter

In 2011, a discrepancy between the values of the Planck constant measured by counting Si atoms and by comparing mechanical and electrical powers prompted a review, among others, of the measurement of the spacing of $^{28}$Si {220} lattice planes, either to confirm the measured value and its uncertainty or to identify errors. This exercise confirmed the result of the previous measurement and yields the additional value $d_{220}=192014711.98(34)$ am having a reduced uncertainty.

physics.data-an↗

X-ray phase contrast topography to measure the surface stress and bulk strain in a silicon crystal

The measurement of the Si lattice parameter by x-ray interferometry assumes the use of strain-free crystals, which might not be true because of intrinsic stresses due to surface relaxation, reconstruction, and oxidation. We used x-ray phase-contrast topography to investigate the strain sensitivity to the finishing, annealing, and coating of the interferometer crystals.We assessed the topography capabilities by measuring the lattice strain due to films of copper deposited on the interferometer mirror-crystal. A byproduct has been the measurement of the surface stresses after complete relaxation of the coatings.

physics.app-ph↗

The correlation of the $N_A$ measurements by counting $^{28}$Si atoms

An additional value of the Avogadro constant was obtained by counting the atoms in isotopically enriched Si spheres. With respect to the previous determination, the spheres were etched and repolished to eliminate metal contaminations and to improve the roundness. In addition, all the input quantities -- molar mass, lattice parameter, mass, and volume -- were remeasured aiming at a smaller uncertainty. In order to make the values given Refs.\ 1 and 2 usable for a least squares adjustment, we report about the estimate of their correlation.

cond-mat.mtrl-sci↗

Diffraction effects in length measurements by laser interferometry

High-accuracy dimensional measurements by laser interferometers require corrections because of diffraction, which makes the effective fringe-period different from the wavelength of a plane (or spherical) wave $λ_0$. By using a combined X-ray and optical interferometer as a tool to investigate diffraction across a laser beam, we observed wavelength variations as large as $10^{-8}λ_0$. We show that they originate from the wavefront evolution under paraxial propagation in the presence of wavefront- and intensity-profile perturbations.

physics.optics↗

The distribution of the electric current in a watt-balance coil

In the watt balance experiments, separate measurements of the magnetic and electromotive forces in a coil in a magnetic field enable a virtual comparison between mechanical and electric powers to be carried out, which lead to an accurate measurement of the Planck constant. This paper investigates the three-dimensional nature of the coil-field interaction and describes the balance operation by a continuous three-dimensional model.

physics.class-ph↗

Direct calorimetric measurements of isothermal entropy change on single crystal W-type hexaferrites at the spin reorientation transition

We report on the magnetic field induced isothermal entropy change, Δs(Ha, T), of W-type ferrite with CoZn substitution. Entropy measurements are performed by direct calorimetry. Single crystals of the composition BaCo$_0.62$Zn$_1.38$Fe$_16$O$_27$, prepared by the flux method, are measured at different fixed temperatures under an applied field perpendicular and parallel to the c axis. At 296 K one deduces a value of K$_1$ = 8.7 \times 10^{4} J m$^-3$ for the first anisotropy constant, which is in good agreement with the literature. The spin reorientation transition temperature is estimated to take place between 200 and 220 K.

cond-mat.mtrl-sci↗