Searcharxiv⌕ Search

arXiv subjects

G. Korcyl

Publications and source records attributed to G. Korcyl.

At least 37 records · Page 2Linked to original sources

PANDA Phase One

The Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, provides unique possibilities for a new generation of hadron-, nuclear- and atomic physics experiments. The future antiProton ANnihilations at DArmstadt (PANDA or $\overline{\rm P}$ANDA) experiment at FAIR will offer a broad physics programme, covering different aspects of the strong interaction. Understanding the latter in the non-perturbative regime remains one of the greatest challenges in contemporary physics. The antiproton-nucleon interaction studied with PANDA provides crucial tests in this area. Furthermore, the high-intensity, low-energy domain of PANDA allows for searches for physics beyond the Standard Model, e.g. through high precision symmetry tests. This paper takes into account a staged approach for the detector setup and for the delivered luminosity from the accelerator. The available detector setup at the time of the delivery of the first antiproton beams in the HESR storage ring is referred to as the \textit{Phase One} setup. The physics programme that is achievable during Phase One is outlined in this paper.

hep-ex↗

The J-PET detector -- a tool for precision studies of ortho-positronium decays

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.

physics.ins-det↗

Correlated pion-proton pair emission off hot and dense QCD matter

In this letter we report the first multi-differential measurement of correlated pion-proton pairs from 2 billion Au+Au collisions at \sqrt{s_{NN}} = 2.42 GeV collected with HADES. In this energy regime the population of Δ(1232) resonances plays an important role in the way energy is distributed between intrinsic excitation energy and kinetic energy of the hadrons in the fireball. The triple differential d3N/dMπpdpTdy distributions of correlated πp pairs have been determined by subtracting the πp combinatorial background using an iterative method. The invariant-mass distributions in the Δ(1232) mass region show strong deviations from a Breit-Wigner function with vacuum width and mass. The yield of correlated pion-proton pairs exhibits a complex isospin, rapidity and transverse-momentum dependence. In the invariant mass range 1.1 < Minv (GeV/c2) < 1.4, the yield is found to be similar for π+p and π-p pairs, and to follow a power law ^α, where is the mean number of participating nucleons. The exponent α depends strongly on the pair transverse momentum (pT) while its pT-integrated and charge-averaged value is α = 1.5 \pm 0.08stat \pm 0.2sys.

nucl-ex↗

Directed, elliptic and higher order flow harmonics of protons, deuterons and tritons in Au+Au collisions at $\sqrt{s_{NN}} = 2.4$ GeV

Flow coefficients $v_{n}$ of the orders $n = 1 - 6$ are measured with the High-Acceptance DiElectron Spectrometer (HADES) at GSI for protons, deuterons and tritons as a function of centrality, transverse momentum and rapidity in Au+Au collisions at $\sqrt{s_{NN}} = 2.4$ GeV. Combining the information from the flow coefficients of all orders allows to construct for the first time, at collision energies of a few GeV, a multi-differential picture of the angular emission pattern of these particles. It reflects the complicated interplay between the effect of the central fireball pressure on the emission of particles and their subsequent interaction with spectator matter. The high precision information on higher order flow coefficients is a major step forward in constraining the equation-of-state of dense baryonic matter.

nucl-ex↗

Proton number fluctuations in $\sqrt{s_{NN}}$ = 2.4 GeV Au+Au collisions studied with HADES

We present an analysis of proton number fluctuations in $\sqrt{s_{NN}}$ = 2.4 GeV Au+Au collisions measured with the High-Acceptance DiElectron Spectrometer (HADES) at GSI. With the help of extensive detector simulations done with IQMD transport model events including nuclear clusters, various nuisance effects influencing the observed proton cumulants have been investigated. Acceptance and efficiency corrections have been applied as a function of fine grained rapidity and transverse momentum bins, as well as considering local track density dependencies. Next, the effects of volume changes within particular centrality selections have been considered and beyond-leading-order corrections have been applied to the data. The efficiency and volume corrected proton number moments and cumulants Kn of orders n = 1, . . . , 4 have been obtained as a function of centrality and phase-space bin, as well as the corresponding correlators C_n . We find that the observed correlators show a power-law scaling with the mean number of protons, i.e. $C_n \propto ^n$, indicative of mostly long-range multi-particle correlations in momentum space. We also present a comparison of our results with Au+Au collision data obtained at RHIC at similar centralities, but higher $\sqrt{s_{NN}}$.

nucl-ex↗

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.

physics.ins-det↗

Identical pion intensity interferometry at sqrt(s_{NN})=2.4 GeV

High-statistics $π^-π^-$ and $π^+π^+$ femtoscopy data are presented for Au+Au collisions at $\sqrt{s_\mathrm{NN}}=2.4$ GeV, measured with HADES at SIS18/GSI. The experimental correlation functions allow the determination of the space-time extent of the corresponding emission sources via a comparison to models. The emission source, parametrized as three-dimensional Gaussian distribution, is studied in dependence on pair transverse momentum, azimuthal emission angle with respect to the reaction plane, collision centrality and beam energy. For all centralities and transverse momenta, a geometrical distribution of ellipsoidal shape is found in the plane perpendicular to the beam direction with the larger extension perpendicular to the reaction plane. For large transverse momenta, the corresponding eccentricity approaches the initial eccentricity. The eccentricity is smallest for most central collisions, where the shape is almost circular. The magnitude of the tilt angle of the emission ellipsoid in the reaction plane decreases with increasing centrality and increasing transverse momentum. All source radii increase with centrality, largely exhibiting a linear rise with the number of participants, irrespective of transverse momentum. A substantial charge-sign difference of the source radii is found, appearing most pronounced at low transverse momentum. The extracted source parameters are consistent with the extrapolation of their energy dependence down from higher energies.

nucl-ex↗

Charged pion production in $\mathbf{Au+Au}$ collisions at $\mathbf{\sqrt{s_{NN}}}$ = 2.4$\mathbf{GeV}$

We present high-statistic data on charged pion emission from Au+Au collisions at $\sqrt{s_{\rm{NN}}}$ = 2.4 GeV (corresponding to $E_{beam}$ = 1.23 A GeV) in four centrality classes in the range 0 - 40$\%$ of the most central collisions. The data are analyzed as a function of transverse momentum, transverse mass, rapidity, and polar angle. Pion multiplicity per participating nucleon decreases moderately with increasing centrality. The polar angular distributions are found to be non-isotropic even for the most central event class. Our results on pion multiplicity fit well into the general trend of the world data, but undershoot by $2.5 σ$ data from the FOPI experiment measured at slightly lower beam energy. We compare our data to state-of-the-art transport model calculations (PHSD, IQMD, PHQMD, GiBUU and SMASH) and find substantial differences between the measurement and the results of these calculations.

nucl-ex↗

Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.

physics.ins-det↗

Two-Pion production in the second resonance region in $π^- p$ collisions with HADES

Pion induced reactions provide unique opportunities for an unambiguous description of baryonic resonances and their coupling channels by means of a partial wave analysis. Using the secondary pion beam at SIS18, the two pion production in the second resonance region has been investigated to unravel the role of the $N(1520) \frac{3}{2}^-$ resonance in the intermediate $ρ$ production. Results on exclusive channels with one pion ($π^{-}p$) and two pions ($π^{+}π^{-}n$, $π^{0}π^{-}p$) in the final state measured in the $π^{-}-p$ reaction at four different pion beam momenta (0.650, 0.685, 0.733, and 0.786 GeV/c) are presented. The excitation function of the different partial waves and $Δπ$, $Nσ$ and $Nρ$ isobar configurations is obtained, using the Bonn-Gatchina partial wave analysis. The $N(1520) \frac{3}{2}^-$ resonance is found to dominate the $Nρ$ final state with the branching ratio $BR=12.2 \pm 1.9\%$.

nucl-ex↗

Optimized implementation of the conjugate gradient algorithm for FPGA-based platforms using the Dirac-Wilson operator as an example

It is now a noticeable trend in High Performance Computing that the systems are becoming more and more heterogeneous. Compute nodes with a host CPU are being equipped with accelerators, the latter being a GPU or FPGA cards or both. In many cases at the heart of scientific applications running on such systems are iterative linear solvers. In this work we present a software package which includes an FPGA implementation of the Conjugate Gradient algorithm using a particular problem of the Dirac-Wilson operator as encountered in numerical simulations of Quantum Chromodynamics. The software is written in OpenCL and C++ and is optimized for maximal performance. Our framework allows for a simple implementation of other linear operators, while keeping the data transport mechanisms unaltered. Hence, our software can serve as a backbone for many applications which are expected to gain a significant boost factor on FPGA accelerators. As such systems are expected to become more and more widespread, the need for highly performant FPGA implementations of the Conjugate Gradient algorithm and its variants will certainly increase and the porting investment can be greatly facilitated by the attached code.

cs.DC↗

Technical Design Report for the PANDA Endcap Disc DIRC

PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.

physics.ins-det↗

Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph. The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV

physics.ins-det↗

Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners

In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include: (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using $2γ$ annihilations, and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Simulations are conducted assuming that radiopharmaceutical is labelled with $^{44}Sc$ isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET, and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution the three cases were considered assuming that CRT is equal to 140ps, 50ps and 10ps. The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences is larger by a factor of 12.2 (for LYSO PET) and by factor of 4.7 (for plastic PET) with respect to the sensitivity for the standard $2γ$ imaging by LYSO PET scanners with AFOV=20cm.

physics.ins-det↗

Investigating the Dirac operator evaluation with FPGAs

In recent years the computational capacity of single Field Programmable Gate Arrays (FPGA) devices as well as their versatility has increased significantly. Adding to that the High Level Synthesis frameworks allowing to program such processors in a high level language like C++, makes modern FPGA devices a serious candidate as building blocks of a general purpose High Performance Computing solution. In this contribution we describe benchmarks which we performed using a Lattice QCD code, a highly compute-demanding HPC academic code for elementary particle simulations. We benchmark the performance of a single FPGA device running in two modes: using the external or embedded memory. We discuss both approaches in detail using the Xilinx U250 device and provide estimates for the necessary memory throughput and the minimal amount of resources needed to deliver optimal performance depending on the available hardware platform.

cs.DC↗

Identical pion intensity interferometry in central Au+Au collisions at 1.23A GeV

We investigate identical pion HBT intensity interferometry for central Au+Au collisions at 1.23A GeV. High-statistics $π^-π^-$ and $π^+π^+$ data are measured with HADES at SIS18/GSI. The radius parameters, derived from the correlation function depending on relative momenta in the longitudinal-comoving system and parametrized as three-dimensional Gaussian distribution, are studied as function of transverse momentum. A substantial charge-sign difference of the source radii is found, particularly pronounced at low transverse momentum. The extracted Coulomb-corrected source parameters agree well with a smooth extrapolation of the center-of-mass energy dependence established at higher energies, extending the corresponding excitation functions down towards a very low energy. Our data would thus rather disfavour any strong energy dependence of the radius parameters in the low energy region.

nucl-ex↗

Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of the interacting photon. Thus registration of multiple photon scatterings with J-PET enables to determine the polarization of the annihilation photons. In this contribution we present estimates on the physical limitation in the accuracy of the polarization determination of $511$~keV photons with the J-PET detector.

physics.ins-det↗

Feasibility study of the positronium imaging with the J-PET tomograph

A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma quantum. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of about 40 ps. Recent Positron Annihilation Lifetime Spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.

physics.ins-det↗