Searcharxiv⌕ Search

arXiv subjects

G. Korcyl

Publications and source records attributed to G. Korcyl.

At least 55 records · Page 3Linked to original sources

Sub-threshold production of K^{0}_{s} mesons and Λ hyperons in Au(1.23A GeV)+Au

We present first data on sub-threshold production of K0 s mesons and Λ hyperons in Au+Au collisions at $\sqrt{s_{NN}}$ = 2.4 GeV. We observe an universal scaling of hadrons containing strangeness, independent of their corresponding production thresholds. Comparing the yields, their scaling, and the shapes of the rapidity and the pt spectra to state-of-the-art transport model (UrQMD, HSD, IQMD) predictions, we find that none of the latter can simultaneously describe all observables with reasonable \c{hi}2 values.

nucl-ex↗

Strong absorption of hadrons with hidden and open strangeness in nuclear matter

We present the first observation of K- and ϕabsorption within nuclear matter by means of π- -induced reactions on C and W targets at an incident beam momentum of 1.7 GeV/c studied with HADES at SIS18/GSI. The double ratio (K-/K+)W / (K-/K+)C is found to be 0.319 \pm 0.009(stat)+0.014-0.012 (syst) indicating a larger absorption of K- in heavier targets as compared to lighter ones. The measured ϕ/K- ratios in π-+C and π^- +W reactions within the HADES acceptance are found to be equal to $0.55 \pm 0.03(stat)+0.06-0.07$ (syst) and to $0.63 \pm 0.05(stat)-0.11+0.11$ (syst), respectively. The similar ratios measured in the two different reactions demonstrate for the first time experimentally that the dynamics of the ϕmeson in nuclear medium is strongly coupled to the K- dynamics. The large difference in the ϕproduction off C and W nuclei is discussed in terms of a strong \phiN in-medium coupling.

nucl-ex↗

Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector

J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 deg (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 deg (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.

physics.ins-det↗

Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy.

physics.ins-det↗

A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry violation operator which can be constructed solely from the annihilation photons momenta before and after the scattering in the detector.

physics.ins-det↗

Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.

physics.ins-det↗

Centrality determination of Au+Au collisions at 1.23A GeV with HADES

The centrality determination for Au+Au collisions at 1.23A GeV, as measured with HADES at the GSI-SIS18, is described. In order to extract collision geometry related quantities, such as the average impact parameter or number of participating nucleons, a Glauber Monte Carlo approach is employed. For the application of this model to collisions at this relatively low centre-of-mass energy of $\sqrt{s_{\mathrm{NN}}} = 2.42$ GeV special investigations were performed. As a result a well defined procedure to determine centrality classes for ongoing analyses of heavy-ion data is established.

nucl-ex↗

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.

physics.ins-det↗

Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner

The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.

physics.med-ph↗

$Σ^0$ production in proton nucleus collisions near threshold

The production of $Σ^{0}$ baryons in the nuclear reaction p (3.5 GeV) + Nb (corresponding to $\sqrt{s_{NN}}=3.18$ GeV) is studied with the detector set-up HADES at GSI, Darmstadt. $Σ^{0}$s were identified via the decay $Σ^{0} \rightarrow Λγ$ with subsequent decays $Λ\rightarrow p π^{-}$ in coincidence with a $e^{+}e^{-}$ pair from either external ($γ\rightarrow e^{+} e^{-}$) or internal (Dalitz decay $γ^{*}\rightarrow e^{+} e^{-}$) gamma conversions. The differential $Σ^0$ cross section integrated over the detector acceptance, i.e. the rapidity interval $0.5 < y < 1.1$, has been extracted as $Δσ_{Σ^{0}} = 2.3 \pm (0.2)^{stat} \pm \left(^{+0.6}_{-0.6}\right)^{sys} \pm (0.2)^{norm}$ mb, yielding the inclusive production cross section in full phase space $σ^{total}_{Σ^{0}} = 5.8 \pm (0.5)^{stat} \pm \left(^{+1.4}_{-1.4}\right)^{sys} \pm (0.6)^{norm} \pm (1.7)^{extrapol}$ mb by averaging over different extrapolation methods. The $Λ_{all}$/$Σ^{0}$ ratio within the HADES acceptance is equal to 2.3 $\pm$ $(0.2)^{stat}$ $\pm$ $(^{+0.6}_{-0.6})^{sys}$. The obtained rapidity and momentum distributions are compared to transport model calculations. The $Σ^{0}$ yield agrees with the statistical model of particle production in nuclear reactions.

nucl-ex↗

Human Tissues Investigation Using PALS Technique

Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.

physics.med-ph↗

Commissioning of the J-PET detector for studies of decays of positronium atoms

The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.

physics.ins-det↗

J-PET: a new technology for the whole-body PET imaging

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.

physics.ins-det↗

Introduction of total variation regularization into filtered backprojection algorithm

In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.

physics.med-ph↗

Three-dimensional image reconstruction in J-PET using Filtered Back Projection method

We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.

physics.ins-det↗

Analysis procedure of the positronium lifetime spectra for the J-PET detector

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.

physics.ins-det↗

Time calibration of the J-PET detector

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.

physics.ins-det↗

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built out from 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results, obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are consistent.

physics.ins-det↗