SearcharxivSearch

arXiv subjects

Guillaume Jourdan

Publications and source records attributed to Guillaume Jourdan.

14 recordsLinked to original sources

Origins of microwave losses in superconducting circuits made with silicon-on-insulator substrates

Silicon-on-insulator technology is widely used to fabricate silicon based devices, from advanced transistors to photonic circuits or nanomechanical systems. Integrating low loss superconducting quantum circuits with silicon-on-insulator substrates enables to couple the advantages offered by the mature silicon technology to the exquisite sensitivity of superconducting circuits. The natural approach, inherited from research in superconducting microwave devices, is to use a substrate made with highly resistive silicon, known for its low level of microwave losses. In this work, using superconducting microwave resonators, we show that counterintuitively, standard resistivity silicon-on-insulator substrates perform better than high resistivity silicon-on-insulator substrates at cryogenic temperatures. In the latter case, the presence of a parasitic sheet conduction at the interface between bulk silicon and silicon oxide acts as the dominant loss mechanism. This parasitic sheet can be suppressed using substrates with intentionally induced traps. In such substrates, losses are ultimately limited by the dielectric losses of the silicon oxide layer. These substrates offer interesting perspectives for the development of superconducting nanoelectromechanical systems. First, the release, i.e. the removal of the silicon oxide, could be limited to the moving parts, thereby maintaining the mechanical integrity of the rest of the device. Additionally, such structure would enhance heat evacuation into the bulk of the substrate which is an issue in current devices such as microwave-to-optics converters.

cond-mat.mes-hall

Multiphysics optomechanical sensing of a liquid on the micron scale

We present an optomechanical device platform for characterization of optical, thermal, and rheological properties of fluids on the micron scale. A suspended silicon microdisk resonator with a vibrating mass of 100 fg and an effective measurement volume of less than a pL is used to monitor properties of different fluids at rest. By employing analytical models for thermo-optical effects, thermal diffusion and fluid-structure interactions, our platform determines the refractive index, thermal conductivity, viscosity, density and compressibility of the fluid, in a compact measurement setup. A single measurement takes as short as 70 microseconds, and the employed power can be less than 100 microwatts, guaranteeing measurement at rest and in thermal equilibrium.

physics.app-ph

A CMOS compatible platform for high impedance superconducting quantum circuits

Aluminium based platforms have allowed to reach major milestones for superconducting quantum circuits. For the next generation of devices, materials that are able to maintain low microwave losses while providing new functionalities, such as large kinetic inductance or compatibility with CMOS platform are sought for. Here we report on a combined direct current (DC) and microwave investigation of titanium nitride lms of dierent thicknesses grown using CMOS compatible methods. For microwave resonators made of TiN lm of thickness $\sim$3 nm, we measured large kinetic inductance LK $\sim$ 240 pH/sq, high mode impedance of $\sim$ 4.2 k$Ω$ while maintaining microwave quality factor $\sim$ 10^5 in the single photon limit. We present an in-depth study of the microwave loss mechanisms in these devices that indicates the importance of quasiparticles and provide insights for further improvement.

cond-mat.other

Real-time sensing with multiplexed optomechanical resonators

Nanoelectromechanical resonators have been successfully used for a variety of sensing applications. Their extreme resolution comes from their small size at the cost of low capture area, making the "needle in a haystack" issue acute. This leads to poor instrument sensitivity and long analysis time. Moreover, electrical transductions are limited in frequency, which limits the achievable mechanical bandwidth again limiting throughput. Multiplexing a large number of high-frequency resonators appears as a solution, but this is complex with electrical transductions. We propose here a route to solve these issues, with a multiplexing scheme for very high frequency optomechanical resonators. We demonstrate the simultaneous frequency measurement of three silicon microdisks resonators fabricated through a Very Large Scale Integration process. The readout architecture is simple and does not degrade the sensing resolutions. This paves the way towards the realization of sensors for multi-parametric analysis, extremely low limit of detection and response time.

physics.app-ph

Optomechanical mass spectrometry

It has been demonstrated in the recent years that nanomechanical mass spectrometry was well suited for the analysis of specific high mass species such as viruses. Still, the exclusive use of one-dimensional devices such as vibrating beams forces a trade-off between analysis time (related to capture area) and mass resolution (inversely proportional to device mass). Such devices also require complex readout schemes to simultaneously monitor multiple resonance modes, in particular when stiffness or shape come into play, which degrades mass resolution. These issues restrict nanomechanical MS to the analysis of species with specific properties. We report here the first demonstration of single-particle mass spectrometry with nano-optomechanical resonators fabricated with a Very Large Scale Integration process. The unique motion sensitivity of optomechanical techniques allows the use of resonators with new topologies. The device introduced here is designed to be impervious to particle position, stiffness or shape, opening the way to the analysis of large aspect ratio biological objects of great significance such as viruses with a tail or fibrils. Compared to top-down beam resonators with electrical read-out and state-of-the-art mass resolution, we show a three-fold improvement in capture area with no resolution degradation, despite the use of a single resonance mode. Short analysis time is in reach thanks to the sensitivity and bandwidth of optomechanical read-out and its compliance with telecom multiplexing techniques.

physics.app-ph

Optomechanical Resonating Probe for Very High Speed Sensing of Atomic Forces

Atomic force spectroscopy and microscopy (AFM) are invaluable tools to characterize nanostructures and biological systems. Most experiments, including state-of-the-art images of molecular bonds, are achieved by driving probes at their mechanical resonance. This resonance reaches the MHz for the fastest AFM micro-cantilevers, with typical motion amplitude of a few nanometres. Next-generation investigations of molecular scale dynamics, including faster force imaging and higher-resolution spectroscopy of dissipative interactions, require more bandwidth and vibration amplitudes below interatomic distance, for non-perturbative short-range tip-matter interactions. Probe frequency is a key parameter to improve bandwidth while reducing Brownian motion, allowing large signal-to-noise for exquisite resolution. Optomechanical resonators reach motion detection at 10^(-18) m.(Hz)^(-1/2), while coupling light to bulk vibration modes whose frequencies largely surpass those of cantilevers. Here we introduce an optically operated resonating optomechanical atomic force probe of frequency 2 decades above the fastest functional AFM cantilevers while Brownian motion is 4 orders below. Based on a Silicon-On-Insulator technology, the probe demonstrates high-speed sensing of contact and non-contact interactions with sub-picometre driven motion, breaking open current locks for faster and finer atomic force spectroscopy.

physics.ins-det

Charge-independent mass spectrometry of single virus capsids above 100MDa with nanomechanical resonators

Most technologies, including conventional mass spectrometry, struggle to measure the mass of particles in the MDa to GDa range. Although this mass range appears optimal for nanomechanical resonators, early nanomechanical-MS systems suffered from prohibitive sample loss, extended analysis time or inadequate resolution. Here, we report on a novel system architecture combining nebulization of the analytes from solution, their efficient transfer and focusing without relying on electromagnetic fields, and the mass measurements of individual particles using nanomechanical resonator arrays. This system determined the mass distribution of ~30 MDa polystyrene nanoparticles with a detection efficiency 6 orders of magnitude higher than previous nanomechanical-MS systems with ion guides, and successfully performed the highest molecular mass measurement to date with less than 1 picomole of bacteriophage T5 105 MDa viral capsids.

physics.app-ph

Single-particle Mass Spectrometry with arrays of frequency-addressed nanomechanical resonators

One of the main challenges to overcome to perform nanomechanical Mass Spectrometry (NEMS-MS) analysis in a practical time frame stems from the size mismatch between the analyte beam and the extremely small nanomechanical detector area. We report here the demonstration of NEMS-MS with arrays of 20 individually addressed nanomechanical resonators where the number of inputs-outputs for the whole array is the same as that of a single resonator. While all resonators within an array are interconnected via two metal levels, each resonator is designed with a distinct resonance frequency which becomes its individual address. In order to perform single-particle Mass Spectrometry, the resonance frequencies of the two first modes of each NEMS within an array are monitored simultaneously. Using such an array, mass spectra of metallic aggregates in the MDa range are acquired with more than one order of magnitude improvement in analysis time due to the increase in capture cross section compared to individual resonators. A 20 NEMS array is probed in 150ms with the same mass limit of detection as a single resonator. Spectra acquired with a conventional Time- of-Flight (TOF) mass spectrometer in the same system show excellent agreement. As individual information for each resonator within the array is retained, the array becomes a particle imager, each resonator acting as a pixel. With this technique, we demonstrate how Mass Spectrometry Imaging (MSI) at the single particle level becomes possible by mapping a 4cm-particle beam in the MDa range and above.

physics.ins-det

Frequency fluctuations in silicon nanoresonators

Frequency stability is key to performance of nanoresonators. This stability is thought to reach a limit with the resonator's ability to resolve thermally-induced vibrations. Although measurements and predictions of resonator stability usually disregard fluctuations in the mechanical frequency response, these fluctuations have recently attracted considerable theoretical interest. However, their existence is very difficult to demonstrate experimentally. Here, through a literature review, we show that all studies of frequency stability report values several orders of magnitude larger than the limit imposed by thermomechanical noise. We studied a monocrystalline silicon nanoresonator at room temperature, and found a similar discrepancy. We propose a new method to show this was due to the presence of frequency fluctuations, of unexpected level. The fluctuations were not due to the instrumentation system, or to any other of the known sources investigated. These results challenge our current understanding of frequency fluctuations and call for a change in practices.

cond-mat.mes-hall

Overcoming limitations of nanomechanical resonators with simultaneous resonances

Dynamic stabilization by simultaneous primary and superharmonic resonances for high order nonlinearity cancellation is demonstrated with an electrostatically-actuated, piezoresistively-transduced nanomechanical resonator. We prove experimentally how the combination of both the third-order nonlinearity cancellation and simultaneous resonances can be used to linearly drive a nanocantilever up to very large amplitudes compared to fundamental limits like pull-in occurrence, opening the way towards resonators with high frequency stability for high-performance sensing or time reference.

cond-mat.mes-hall

In-plane nanoelectromechanical resonators based on silicon nanowire piezoresistive detection

We report an actuation/detection scheme with a top-down nano-electromechanical system for frequency shift-based sensing applications with outstanding performance. It relies on electrostatic actuation and piezoresistive nanowire gauges for in-plane motion transduction. The process fabrication is fully CMOS compatible. The results show a very large dynamic range (DR) of more than 100dB and an unprecedented signal to background ratio (SBR) of 69dB providing an improvement of two orders of magnitude in the detection efficiency presented in the state of the art in NEMS field. Such a dynamic range results from both negligible 1/f-noise and very low Johnson noise compared to the thermomechanical noise. This simple low-power detection scheme paves the way for new class of robust mass resonant sensor.

cond-mat.mes-hall

Mechanical mode dependence of bolometric back-action in an AFM microlever

Two back action (BA) processes generated by an optical cavity based detection device can deeply transform the dynamical behavior of an AFM microlever: the photothermal force or the radiation pressure. Whereas noise damping or amplifying depends on optical cavity response for radiation pressure BA, we present experimental results carried out under vacuum and at room temperature on the photothermal BA process which appears to be more complex. We show for the first time that it can simultaneously act on two vibration modes in opposite direction: noise on one mode is amplified whereas it is damped on another mode. Basic modeling of photothermal BA shows that dynamical effect on mechanical mode is laser spot position dependent with respect to mode shape. This analysis accounts for opposite behaviors of different modes as observed.

physics.optics

Quantitative non contact dynamic Casimir force measurements

We show that the Casimir force gradient can be quantitatively measured with no contact involved. Results of the Casimir force measurement with systematic uncertainty of 3% are presented for the distance range of 100-600 nm. The statistical uncertainty is shown to be due to the thermal fluctuations of the force probe. The corresponding signal to noise ratio equals unity at the distance of 600 nm. Direct contact between surfaces used in most previous studies to determine absolute distance separation is here precluded. Use of direct contact to identify the origin of distances is a severe limitation for studies of the Casimir forces on structured surfaces as it deteriorates irreversibly the studied surface and the probe. This force machine uses a dynamical method with an inserted gold sphere probe glued to a lever. The lever is mechanically excited at resonant frequency in front of a chosen sample. The absolute distance determination is achieved to be possible, without any direct probe/sample contact, using an electrostatic method associated to a real time correction of the mechanical drift. The positioning shift uncertainty is as low as 2 nm.

physics.gen-ph

Tuning the effective coupling of an AFM lever to a thermal bath

Fabrication of Nano-Electro-Mechanical-Systems (NEMS) of high quality is nowadays extremely efficient. These NEMS will be used as sensors and actuators in integrated systems. Their use however raises questions about their interface (actuation, detection, read out) with external detection and control systems. Their operation implies many fundamental questions related to single particle effects such as Coulomb blockade, light matter interactions such as radiation pressure, thermal effects, Casimir forces and the coupling of nanosystems to external world (thermal fluctuations, back action effect). Here we specifically present how the damping of an oscillating cantilever can be tuned in two radically different ways: i) through an electro-mechanical coupling in the presence of a strong Johnson noise, ii) through an external feedback control of thermal fluctuations which is the cold damping closely related to Maxwell's demon. This shows how the interplay between MEMS or NEMS external control and their coupling to a thermal bath can lead to a wealth of effects that are nowadays extensively studied in different areas.

cond-mat.mtrl-sci