Searcharxiv⌕ Search

arXiv subjects

Henry N. Chapman

Publications and source records attributed to Henry N. Chapman.

At least 37 records · Page 2Linked to original sources

Absolute spectral metrology of XFEL pulses using diffraction in crystals

At modern X-ray sources, such as synchrotrons and X-ray Free-Electron Lasers (XFELs), it is important to measure the absolute value of the photon energy directly. Here, a method for absolute spectral metrology is presented. A photon energy estimation method based on the spectral measurements and rocking of diffracting crystals is presented. The photon energy of SASE1 channel of the European XFEL was measured, and the benefits and applications of the precise photon energy evaluation are discussed.

physics.ins-det↗

Decreasing ultrafast X-ray pulse durations with saturable absorption and resonant transitions

Saturable absorption is a nonlinear effect where a material's ability to absorb light is frustrated due to a high influx of photons and the creation of electron vacancies. Experimentally induced saturable absorption in copper revealed a reduction in the temporal duration of transmitted X-ray laser pulses, but a complete understanding of this process is still missing. In this computational work, we employ non-local thermodynamic equilibrium plasma simulations to study the interaction of femtosecond X-rays and copper. Following the onset of frustrated absorption, we find that a $K\text{--}M$ resonant transition occurring at highly charged states turns copper opaque again. The changes in absorption generate a transient transparent window responsible for the shortened transmission signal. We also propose using fluorescence induced by the incident beam as an alternative source to achieve shorter X-ray pulses. Intense femtosecond X-ray pulses are valuable to probe the structure and dynamics of biological samples or to reach extreme states of matter. Shortened pulses could be relevant for emerging imaging techniques.

physics.plasm-ph↗

On the use of multilayer Laue lenses with X-ray Free Electron Lasers

Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.

physics.acc-ph↗

Deep Iterative Phase Retrieval for Ptychography

One of the most prominent challenges in the field of diffractive imaging is the phase retrieval (PR) problem: In order to reconstruct an object from its diffraction pattern, the inverse Fourier transform must be computed. This is only possible given the full complex-valued diffraction data, i.e. magnitude and phase. However, in diffractive imaging, generally only magnitudes can be directly measured while the phase needs to be estimated. In this work we specifically consider ptychography, a sub-field of diffractive imaging, where objects are reconstructed from multiple overlapping diffraction images. We propose an augmentation of existing iterative phase retrieval algorithms with a neural network designed for refining the result of each iteration. For this purpose we adapt and extend a recently proposed architecture from the speech processing field. Evaluation results show the proposed approach delivers improved convergence rates in terms of both iteration count and algorithm runtime.

eess.IV↗

Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging

One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.

eess.IV↗

Optical funnel to guide and focus virus particles for X-ray laser imaging

The need for precise manipulation of nanoparticles in gaseous or near-vacuum environments is encountered in many studies that include aerosol morphology, nanodroplet physics, nanoscale optomechanics, and biomolecular physics. Photophoretic forces, whereby momentum exchange between a particle and surrounding gas is induced with optical light, were recently shown to be a robust means of trapping and manipulating nanoparticles in air. We previously proposed a photophoretic "optical funnel" concept for the delivery of bioparticles to the focus of an x-ray free-electron laser (XFEL) beam for femtosecond x-ray diffractive imaging. Here, we describe the formation of a high-aspect-ratio optical funnel and provide a first experimental demonstration of this concept by transversely compressing and concentrating a high-speed beam of aerosolized viruses by a factor of three in a low-pressure environment. These results pave the way toward improved sample delivery efficiency for XFEL imaging experiments as well as other forms of imaging and spectroscopy.

physics.optics↗

New aerodynamic lens injector for single particle diffractive imaging

An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction patterns of polystyrene spheres are modeled using Mie scattering, which allowed for the characterization of the particle beam under diffractive-imaging conditions and yield good agreement with particle-trajectory simulations.

physics.ins-det↗

3D diffractive imaging of nanoparticle ensembles using an X-ray laser

We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.

physics.app-ph↗

A ray-trace analysis of X-ray multilayer Laue lenses for nanometer focusing

Thick diffractive optical elements offer a promising way to achieve focusing or imaging at a resolution approaching 1 nm for X-ray wavelengths shorter than about 0.1 nm. Efficient focusing requires that these are fabricated with structures that vary in period and orientation so that rays obey Bragg's law over the entire lens aperture and give rise to constructive interference at the focus. Here the analysis method of ray-tracing of thick diffractive optical elements is applied to such lenses to optimise their designs and to investigate their operating and manufacturing tolerances. Expressions are provided of the fourth-order series expansions of the wavefront aberrations and transmissions of both axi-symmetric lenses and pairs of crossed lenses that each focuses in only one dimension like a cylindrical lens. We find that aplanatic zone-plate designs, whereby aberrations are corrected over a large field of view, can be achieved by axi-symmetric lenses but not the crossed lenses. We investigate the performance of 1 nm-resolution lenses with focal lengths of about 1 mm and show their fields of view are mainly limited by the acceptance angle of Bragg diffraction, and that aberrations can limit the performance of lenses with longer focal lengths. We apply the ray-tracing formalism for a tolerancing analysis of imperfect lenses and examine some strategies for the correction of their aberrations.

physics.optics↗

Low-signal limit of X-ray single particle imaging

An outstanding question in X-ray single particle imaging experiments has been the feasibility of imaging sub 10-nm-sized biomolecules under realistic experimental conditions where very few photons are expected to be measured in a single snapshot and instrument background may be significant relative to particle scattering. While analyses of simulated data have shown that the determination of an average image should be feasible using Bayesian methods such as the EMC algorithm, this has yet to be demonstrated using experimental data containing realistic non-isotropic instrument background, sample variability and other experimental factors. In this work, we show that the orientation and phase retrieval steps work at photon counts diluted to the signal levels one expects from smaller molecules or with weaker pulses, using data from experimental measurements of 60-nm PR772 viruses. Even when the signal is reduced to a fraction as little as 1/256, the virus electron density determined using ab initio phasing is of almost the same quality as the high-signal data. However, we are still limited by the total number of patterns collected, which may soon be mitigated by the advent of high repetition-rate sources like the European XFEL and LCLS-II.

eess.IV↗

Ptychographic X-ray Speckle Tracking

We present a method for the measurement of the phase gradient of a wavefront by tracking the relative motion of speckles in projection holograms as a sample is scanned across the wavefront. By removing the need to obtain an un-distorted reference image of the sample, this method is suitable for the metrology of highly divergent wavefields. Such wavefields allow for large magnification factors, that, according to current imaging capabilities, will allow for nano-radian angular sensitivity and nano-scale sample projection imaging. Both the reconstruction algorithm and the imaging geometry are nearly identical to that of ptychography, except that the sample is placed downstream of the beam focus and that no coherent propagation is explicitly accounted for. Like other x-ray speckle tracking methods, it is robust to low-coherence x-ray sources making is suitable for lab based x-ray sources. Likewise it is robust to errors in the registered sample positions making it suitable for x-ray free-electron laser facilities, where beam pointing fluctuations can be problematic for wavefront metrology. We also present a modified form of the speckle tracking approximation, based on a second-order local expansion of the Fresnel integral. This result extends the validity of the speckle tracking approximation and may be useful for similar approaches in the field.

physics.optics↗

Ptychographic X-ray Speckle Tracking with Multi Layer Laue Lens Systems

The ever-increasing brightness of synchrotron radiation sources demands improved x-ray optics to utilise their capability for imaging and probing biological cells, nano-devices, and functional matter on the nanometre scale with chemical sensitivity. Hard x-rays are ideal for high-resolution imaging and spectroscopic applications due to their short wavelength, high penetrating power, and chemical sensitivity. The penetrating power that makes x-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques that have enabled the fabrication of a series of highly focusing x-ray lenses, known as wedged multi layer Laue lenses. Improvements to the lens design and fabrication technique demands an accurate, robust, in-situ and at-wavelength characterisation method. To this end, we have developed a modified form of the speckle-tracking wavefront metrology method, the ptychographic x-ray speckle tracking method, which is capable of operating with highly divergent wavefields. A useful by-product of this method, is that it also provides high-resolution and aberration-free projection images of extended specimens. We report on three separate experiments using this method, where we have resolved ray path angles to within 4 nano-radians with an imaging resolution of 45nm (full-period). This method does not require a high degree of coherence, making it suitable for lab based x-ray sources. Likewise it is robust to errors in the registered sample positions making it suitable for x-ray free-electron laser facilities, where beam pointing fluctuations can be problematic for wavefront metrology.

physics.optics↗

speckle-tracking: a Software Suite for Ptychographic X-ray Speckle Tracking

In recent years, x-ray speckle tracking techniques have emerged as viable tools for wavefront metrology and sample imaging applications. These methods are based on the measurement of near-field images. Thanks to the simple experimental set-up, high angular sensitivity and compatibility with low coherence sources these methods have been actively developed for use with synchrotron and laboratory light sources. Not only do speckle-tracking techniques give the potential for high resolution imaging, but they also provide rapid and robust characterisation of aberrations of x-ray optical elements, focal spot profiles and the sample position and transmission properties. In order to realise these capabilities, we require software implementations that are equally rapid and robust. To address this need, a software suite has been developed for the "ptychographic x-ray speckle tracking technique" -- an x-ray speckle based method suitable for highly divergent wavefields. The software suite is written in Python 3, with an OpenCL back end for GPU and multi-CPU core processing. It is accessible as a Python module, through the command line or through a graphical user interface and is available as source code under version 3 or later of the GNU General Public License.

eess.IV↗

X-ray diffractive imaging of controlled gas-phase molecules: Toward imaging of dynamics in the molecular frame

We report experimental results on the diffractive imaging of three-dimensionally aligned 2,5-diiodothiophene molecules. The molecules were aligned by chirped near-infrared laser pulses, and their structure was probed at a photon energy of 9.5 keV ($λ\approx130 \text{pm}$) provided by the Linac Coherent Light Source. Diffracted photons were recorded on the CSPAD detector and a two-dimensional diffraction pattern of the equilibrium structure of 2,5-diiodothiophene was recorded. The retrieved distance between the two iodine atoms agrees with the quantum-chemically calculated molecular structure to within 5 %. The experimental approach allows for the imaging of intrinsic molecular dynamics in the molecular frame, albeit this requires more experimental data which should be readily available at upcoming high-repetition-rate facilities.

physics.atm-clus↗

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

physics.ins-det↗

The natural breakup length of a steady capillary jet

Despite their fundamental and applied importance, a general model to predict the natural breakup length of steady capillary jets has not been proposed yet. In this work, we derive a scaling law with two universal constants to calculate that length as a function of the liquid properties and operating conditions. These constants are determined by fitting the scaling law to a large set of experimental and numerical measurements, including previously published data. Both the experimental and numerical jet lengths conform remarkably well to the proposed scaling law. This law is explained in terms of the growth of perturbations excited by the jet breakup itself.

physics.flu-dyn↗

Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources

We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.

physics.ins-det↗

Thermal x-ray diffraction and near-field phase contrast imaging

Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imaging (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such schemes is minimal compared to the methods that achieve similar effects by using entangled x-ray photon pairs.

physics.optics↗