Direct Terrestrial Test of Lorentz Symmetry in Electrodynamics to 10$^{-18}$

Lorentz symmetry is a foundational property of modern physics, underlying the standard model of particles and general relativity. It is anticipated that these two theories are low energy approximations of a single theory that is unified and consistent at the Planck scale. Many unifying proposals allow Lorentz symmetry to be broken, with observable effects appearing at Planck-suppressed levels; thus precision tests of Lorentz invariance are needed to assess and guide theoretical efforts. Here, we use ultra-stable oscillator frequency sources to perform a modern Michelson-Morley experiment and make the most precise direct terrestrial test to date of Lorentz symmetry for the photon, constraining Lorentz violating orientation-dependent relative frequency changes $Δν$/$ν$ to 9.2$\pm$10.7$\times10^{-19}$ (95$\%$ confidence interval). This order of magnitude improvement over previous Michelson-Morley experiments allows us to set comprehensive simultaneous bounds on nine boost and rotation anisotropies of the speed of light, finding no significant violations of Lorentz symmetry.

hep-ph↗

Stability measurements of microwave frequency synthesis with liquid helium cooled cryogenic sapphire oscillators

We report on the evaluation of microwave frequency synthesis using two cryogenic sapphire oscillators developed at the University of Western Australia. A down converter is used to make comparisons between microwave clocks at different frequencies, where the synthesized signal has a stability not significantly different from the reference oscillator. By combining the CSO with a H-maser, a reference source of arbitrary frequency at X-band can be synthesized with a fractional frequency stability of sub-$4 \times 10^{-15}$ for integration times between 1 s and 10,000 s.

physics.ins-det↗

Observation of persistent photoconductivity in bulk Gallium Arsenide and Gallium Phosphide samples at cryogenic temperatures using the Whispering Gallery mode method

Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at cryogenics temperatures < 50 K. In both cases persistent photoconductivity was observed after initially exposing semiconductors to white light from a halogen lamp. Photoconductance decay time constants for GaP and GaAs were determined to be 0.900 +/- 0.081 ns and 1.098 +/- 0.063 ns, respectively, using this method.

physics.optics↗

Modified permittivity observed in bulk Gallium Arsenide and Gallium Phosphide samples at 50 K using the Whispering Gallery mode method

Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at 50 K. In both samples we observed change in permittivity under light and dark conditions. This results from a change in the polarization state of the semiconductor, which is consistent with a free electron-hole creation/recombination process. The permittivity of the semiconductor is modified by free photocarriers in the surface layers of the sample which is the region sampled by Whispering Gallery modes.

physics.optics↗

Cryogenic sapphire oscillator with exceptionally high long-term frequency stability

We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.

physics.ins-det↗

Long Term Operation and Performance of Cryogenic Sapphire Oscillators

Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.

physics.ins-det↗

The Carmeli metric correctly describes spiral galaxy rotation curves

The metric by Carmeli accurately produces the Tully-Fisher type relation in spiral galaxies, a relation showing the fourth power of the rotation speed proportional to the mass of the galaxy. And therefore it is claimed that it is also no longer necessary to invoke dark matter to explain the anomalous dynamics in the arms of spiral galaxies. An analysis is presented here showing Carmeli?s 5 dimensional space-time-velocity metric can also indeed describe the rotation curves of spiral galaxies based on the properties of the metric alone.

gr-qc↗

Carmeli's accelerating universe is spatially flat without dark matter

Carmeli's 5D brane cosmology has been applied to the expanding accelerating universe and it has been found that the distance redshift relation will fit the data of the high-z supernova teams without the need for dark matter. Also the vacuum energy contribution to gravity indicates that the universe is asymptotically expanding towards a spatially flat state, where the total mass/energy density tends to unity.

gr-qc↗