SearcharxivSearch

arXiv subjects

Jianbei Liu

Publications and source records attributed to Jianbei Liu.

At least 19 recordsLinked to original sources

A Novel Segment-Based Tracking Algorithm for HLT under High-Occupancy and Complex Conditions

In the High-Level Trigger (HLT) of both electron-positron and hadron collision experiments, the tracking process for large-volume gaseous detectors typically consumes a latency of hundreds of milliseconds. Upgrades of existing experiments and the development of next-generation facilities demand enhanced HLT tracking performance: handling higher detector occupancy and suppressing latency. To address high occupancy conditions, a novel HLT tracking algorithm based on track segments is proposed. This method involves constructing a pattern bank comprising 11 pre-defined patterns, optimizing edge-matrix formation using position, momentum, and timing criteria, and merging stereo superlayer segments to improve track consistency. These measures significantly reduce the number of stored segments and the size of the edge matrix, thereby lowering the complexity of global tracking. Even at 25\% occupancy, the number of elements for global tracking is reduced to approximately 400-500, while the density of the edge matrix remains below 1\%. With the depth-first search within connected components, the simulation results show that the algorithm maintains stable performance with occupancy ranging from 5\% to 25\%, achieving a data compression ratio of approximately 50\% to 70\%. Validation against the STCF offline reconstruction algorithm confirms that the HLT algorithm preserves high signal-hit retention without introducing significant adverse effects on offline tracking efficiency or on the reconstruction. These results demonstrate that the proposed algorithm can retain high-quality signal hits across a broad range of occupancy levels, indicating a strong potential for further development and adaptation to even more challenging, high-luminosity experimental conditions.

physics.ins-det

A Low Background Beta Detection System using a Time Projection Chamber

In this paper, we present a Time Projection Chamber (TPC) system for low-background beta radiation measurements. The system consists of a TPC with two-dimensional-strip readout Micromegas and an anti-coincidence detector with readout pads for cosmic ray veto. The detector system utilize an AGET-based waveform sampling system for data acquisition. The beta detection capability of the system was verified through experimental test using $^{90}$Sr beta source. Additionally, a dedicated simulation program based on Geant4 was developed to model the entire detection process, including responses to both the beta source and background radiation. Simulation results were compared with experimental data for both beta and background samples, showing good agreements. The simulation samples were utilized to optimize and train classification models for beta and background discrimination. By applying the selected model into test data, the system achieved a background rate of 0.49 $\rm cpm/cm^2$ while retaining more than 55% of $^{90}$Sr beta signals within a 7 cm diameter detection region. Further analysis revealed that approximately 70% of the background originates from environmental gamma radiation, while the remaining contribution mainly comes from intrinsic radioactivity of detector materials, particularly the FR-4 based field cage and readout plane. Based on the knowledge gained from the experiments and simulations, an optimization of the TPC system has been proposed, with simulation predicting a potential reduction of the background rate to 0.0012 $\rm cpm/cm^2$.

physics.ins-det

Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector

The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a Cherenkov radiator with a two-stage Micromegas amplification structure. To improve operational robustness, a resistive anode has been implemented using a DLC layer deposited on a Kapton substrate. While this design enhances detector stability, the resistive layer may influence rate capability, signal formation, and detector capacitance, altering timing performance. This work presents a comprehensive study of a resistive design, including an analytical model and finite-element simulations to quantify rate-dependent gain reduction due to ohmic voltage drop on the resistive layer. An analytical solution for the voltage across a finite-size resistive layer is derived, and a numerical model is developed to evaluate gain suppression under intense particle fluxes. The impact of the resistive layer on signal formation is investigated using time-dependent weighting fields and the Garfield++ simulation framework. The contribution of signal components induced by the resistive layer is quantified, and preservation of the signal leading edge is found for surface resistivities above 100 kohm per square. Single-channel resistive-anode prototypes were designed, constructed, and experimentally characterized. Laboratory measurements using single photoelectrons and power spectral density analysis show the predicted reduction in signal amplitude while preserving the leading edge. Muon beam tests with CsI and DLC photocathodes demonstrate a time resolution of 11.5 ps for CsI, comparable to 11.9 ps for the metallic-anode device, showing the suitability of the resistive design for precision timing applications.

physics.ins-det

Simulation of MAPS and a MAPS-based Inner Tracker for the Super Tau-Charm Facility

Monolithic Active Pixel Sensors (MAPS) are a promising detector candidate for the inner tracker of the Super Tau-Charm Facility (STCF). To evaluate the performance of MAPS and the MAPS-based inner tracker, a dedicated simulation workflow has been developed, offering essential insights for detector design and optimization. The intrinsic characteristics of MAPS, designed using several fabrication processes and pixel geometries, were investigated through a combination of Technology Computer Aided Design (TCAD) and Monte Carlo simulations. Simulations were conducted with both minimum ionizing particles and $^{55}$Fe X-rays to assess critical parameters such as detection efficiency, cluster size, spatial resolution, and charge collection efficiency. Based on these evaluations, a MAPS sensor featuring a strip-like pixel and a high-resistivity epitaxial layer is selected as the baseline sensor design for the STCF inner tracker due to its excellent performance. Using this optimized MAPS design, a three-layer MAPS-based inner tracker was modeled and simulated. The simulation demonstrated an average detection efficiency exceeding 99%, spatial resolutions of 44.8$\rm{μm}$ in the $z$ direction and 8.2$\rm{μm}$ in the $r-ϕ$ direction, and an intrinsic sensor time resolution of 5.9ns for 1GeV/c $μ^-$ particles originating from the interaction point. These promising results suggest that the MAPS-based inner tracker fulfills the performance requirements of the STCF experiment.

physics.ins-det

Optimization of gain uniformity in thermal bonding Micromegas for the PandaX-III experiment

Micro-pattern gas detectors (MPGDs) are widely utilized in physics experiments owing to their excellent spatial resolution and high-rate capabilities. Within the PandaX-III experiment, which aims to investigate neutrinoless double beta decay, Micromegas detectors serve as charge readout devices. High energy resolution is a critical requirement for the readout plane in this context, and gain uniformity significantly impacts the achievable resolution, primarily because of the extended tracks of primary ionization electrons. However, scaling up MPGDs to larger active areas exacerbates the challenge of maintaining gain uniformity, and effectively controlling the uniformity of the avalanche gap is a key factor in the detector manufacturing process via the thermal bonding method. This study demonstrates that optimizing the thermal bonding films specifically at the detector edges can effectively improve the gain uniformity, achieving a gain uniformity of < 5% over the entire 200*200 mm2 active area in a 1 bar Ar/isobutane (96.5/3.5) gas mixture. Additionally, the gain uniformity of approximately 14% was characterized at high pressures of up to 10 bar, revealing promising potential for high resolution measurements in the PandaX-III experiment and other high-pressure applications.

physics.ins-det

Development of the CEPC analog hadron calorimeter prototype

The Circular Electron Positron Collider (CEPC) is a next-generation electron$-$positron collider proposed for the precise measurement of the properties of the Higgs boson. To emphasize boson separation and jet reconstruction, the baseline design of the CEPC detector was guided by the particle flow algorithm (PFA) concept. As one of the calorimeter options, the analogue hadron calorimeter (AHCAL) was proposed. The CEPC AHCAL comprises a 40-layer sandwich structure using steel plates as absorbers and scintillator tiles coupled with silicon photomultipliers (SiPM) as sensitive units. To validate the feasibility of the AHCAL option, a series of studies were conducted to develop a prototype. This AHCAL prototype underwent an electronic test and a cosmic ray test to assess its performance and ensure it was ready for three beam tests performed in 2022 and 2023. The test beam data is currently under analysis, and the results are expected to deepen our understanding of hadron showers, validate the concept of Particle Flow Algorithm (PFA), and ultimately refine the design of the CEPC detector.

physics.ins-det

New Physics Search at the CEPC: a General Perspective

The Circular Electron-Positron Collider (CEPC), a proposed next-generation Higgs factory, provides new opportunities to explore physics beyond the Standard Model (SM). With its clean electron-positron collision environment and the ability to collect large samples of Higgs, W, and Z bosons, the CEPC enables precision measurements and searches for new physics. This white paper outlines the CEPC's discovery potential, including studies of exotic decays of the Higgs, Z, and top quarks, dark matter and dark sector phenomena, long-lived particles, supersymmetry, and neutrino-related signatures. Advanced detector technologies and reconstruction techniques, such as one-to-one correspondence reconstruction and jet origin identification, significantly improve sensitivity to rare and weakly interacting processes. The CEPC is particularly well suited to probe the electroweak phase transition and test models of electroweak baryogenesis and dark sector interactions. In addition, global fit analyses highlight the CEPC's complementary role in constraining a wide range of new physics scenarios. These features position the CEPC as a powerful tool for exploring the next frontier in fundamental particle physics in the post-Higgs discovery era.

hep-ex

Flavor Physics at the CEPC: a General Perspective

We discuss the landscape of flavor physics at the Circular Electron-Positron Collider (CEPC), based on the nominal luminosity outlined in its Technical Design Report. The CEPC is designed to operate in multiple modes to address a variety of tasks. At the $Z$ pole, the expected production of 4 Tera $Z$ bosons will provide unique and highly precise measurements of $Z$ boson couplings, while the substantial number of boosted heavy-flavored quarks and leptons produced in clean $Z$ decays will facilitate investigations into their flavor physics with unprecedented precision. We investigate the prospects of measuring various physics benchmarks and discuss their implications for particle theories and phenomenological models. Our studies indicate that, with its highlighted advantages and anticipated excellent detector performance, the CEPC can explore beauty and $τ$ physics in ways that are superior to or complementary with the Belle II and Large-Hadron-Collider-beauty experiments, potentially enabling the detection of new physics at energy scales of 10 TeV and above. This potential also extends to the observation of yet-to-be-discovered rare and exotic processes, as well as testing fundamental principles such as lepton flavor universality, lepton and baryon number conservation, etc., making the CEPC a vibrant platform for flavor physics research. The $WW$ threshold scan, Higgs-factory operation and top-pair productions of the CEPC further enhance its merits in this regard, especially for measuring the Cabibbo-Kobayashi-Maskawa matrix elements, and Flavor-Changing-Neutral-Current physics of Higgs boson and top quarks. We outline the requirements for detector performance and considerations for future development to achieve the anticipated scientific goals.

hep-ex

A Low Power Monolithic Active Pixel Sensor Prototype for the STCF Inner Tracker

The Super Tau-Charm Facility (STCF) is a proposed $e^+e^-$ collider with a peak luminosity 100 times higher than that of the present tau-charm factory. The inner tracker (ITK) of STCF should feature a low material budget and high readout speed. Under these requirements, the monolithic active pixel sensor (MAPS) is considered as a promising candidate for the ITK. To minimize the power consumption of MAPS (for low material budget), larger-size sensors are proposed to reduce the scale of the readout circuitry while preserving the required position resolution. Multiple sensors with varying dimensions and structures were designed and integrated in several prototype chips for performance comparison, fabricated in a 180~nm CIS process. The in-pixel readout circuit can also provide time of arrival (ToA) and time-over-threshold (ToT) of the hit signal, with a least significant bit (LSB) of 50 ns. The peripheral readout circuit performs operations including timestamp correction, data aggregation, caching, framing, 8b/10b encoding, and serialization. According to simulation, the power consumption for a full-scale chip is about 55.7 mW/cm2. Preliminary measurements have been conducted on the prototype chips.

physics.ins-det

Global track finding based on the Hough transform in the STCF detector

The proposed Super Tau-Charm Facility (STCF) is an electron-positron collider designed to operate in a center-of-mass energy range from 2 to 7 GeV. It provides a unique platform for physics research in the tau-charm energy region. To fulfill the physics goals of STCF, high tracking efficiency and good momentum resolution is required for charged particles with momenta from 50 MeV/c to 3.5 GeV/c. A global track finding algorithm based on Hough transform has been developed and implemented in the STCF software framework to meet this requirement. The design of the algorithm and its performance with simulation are presented in this paper.

hep-ex

Optimizing Neon-based Gas Mixtures for Two-stage Amplification Fast-timing Micromegas Detectors

Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a simulation study based on Garfield++ that aims to enhance the performance of such detectors by exploring different gas mixtures. The properties of various gas compositions and their impact on detector performance including gain uniformity and time resolution were investigated in the simulation study. The gain uniformity and single-photon time resolution of the detector were evaluated in tests using a multi-channel PICOSEC Micromegas (MM) prototype with different gas mixtures. The experimental results are consistent with the findings of the simulation. Both simulation and experimental results indicate that a higher concentration of neon improves the detector's gain uniformity, while the impact of gas mixtures on time resolution should also be considered as a critical performance indicator. The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance.

physics.ins-det

Study of residual artificial neural network for particle identification in the CEPC high-granularity calorimeter prototype

Particle Identification (PID) plays a central role in associating the energy depositions in calorimeter cells with the type of primary particle in a particle flow oriented detector system. In this paper, we propose novel PID methods based on the Residual Network (ResNet) architecture which enable the training of very deep networks, bypass the need to reconstruct feature variables, and ensure the generalization ability among various geometries of detectors, to classify electromagnetic showers and hadronic showers. Using Geant4 simulation samples with energy ranging from 5 GeV to 120 GeV, the efficacy of Residual Connections is validated and the performance of our model is compared with Boosted Decision Trees (BDT) and other pioneering Artificial Neural Network (ANN) approaches. In shower classification, we observe an improvement in background rejection over a wide range of high signal efficiency ($> 95\%$). These findings highlight the prospects of ANN with Residual Blocks for imaging detectors in the PID task of particle physics experiments.

hep-ex

A large area, high counting rate micromegas-based neutron detector for BNCT

Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of the detectors used in BNCT only have a small detection area, leading to the inconvenience of the full-scale 2-D measurement of the beam. Based on micromegas technology, we designed a neutron detector with large detection area and high counting rate. This detector has a detection area of 288 mm multiples 288 mm and can measure thermal, epithermal, and fast neutrons with different detector settings. The BNCT experiments demonstrated that this detector has a very good 2-D imaging performance for the thermal, epithermal, fast neutron and gamma components, a highest counting rate of 94 kHz/channel, and a good linearity response to the beam power. Additionally, the flux fraction of each component can be calculated based on the measurement results. The Am-Be neutron source experiment indicates that this detector has a spatial resolution of approximately 1.4 mm, meeting the requirements of applications in BNCT. It is evident that this micromegas-based neutron detector with a large area and high counting rate capability has great development prospects in BNCT beam monitoring and evaluation applications.

physics.ins-det

A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

physics.ins-det

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

physics.ins-det

A Light Yield Enhancement Method Using Wavelength Shifter for the STCF EMC

Super Tau-Charm Facility (STCF) is a next-generation high luminosity electron-positron collider facility and is currently one of the major options for accelerator-based particle physics experiment in China. The crystal-based electromagnetic calorimeter (EMC) with undoped CsI is a major sub-system of the STCF spectrometer. To fulfill the increasing physics requirements on measurement precision and the suffering of radiation, improving the detected light yield is an important task of STCF EMC R&D. This paper studies a "wavelength shifting in propagation" scheme for STCF EMC using the nanostructured organosilicon luminophore (NOL). The studies are performed by both Monte Carlo simulation and experimental tests. The light yield is proved to be improved by a factor of 1.59 in the experiment. Meanwhile, a study of the NOL's radiation hardness is carried out to verify the reliability of the NOL. No obvious degradation in the performance is observed with the total ionization does up to 100 krad, far beyond the total radiation dose of STCF with ten years of operation.

physics.ins-det

Study of Hybrid MicroPattern Gas Detector with CsI Photocathode For Super Tau-Charm Factory RICH

Super tau-Charm facility(STCF) is a future electron-position collider operating at tau-Charm energy region aimed to study hadron structure and spectroscopy. The baseline design of the STCF barrel particle identification(PID) detector in the momentum range up to 2 GeV/c is provided by a Ring Imaging Cherenkov Counter(RICH). The architecture of the RICH is an approximately focusing design with liquid perfluorohexane sealed in the quartz container as radiator and a hybrid combination of a CsI coated layers of THGEMs and a Micromegas as the photo-electron detector. A 16*16 cm^2 prototype with quartz radiator has been built and tested at DESY. It was stably operated with 10^5 effective gain. In this paper, the design, the performance, the reconstruction algorithm and the systematic error for single photon electron angular resolution in the aspect of RICH detectors are discusses.

physics.ins-det

DIRC-like time-of-flight detector for the experiment at the Super Tau-Charm Facility

The Super Tau-Charm Facility (STCF) is a future electron-positron collider proposed in China with a peak luminosity of above 0.5$\times$10$^{35}$ cm$^{-2}$s$^{-1}$ and center-of-mass energy ranging from 2 to 7 GeV. An excellent particle identification (PID) capability is one of the most important requirements for the detector at the STCF. A 3$σ$ $π$/K separation power at the momentum of up to 2 GeV/c is required within the detector acceptance. A DIRC-like time-of-flight (DTOF) detector is proposed to meet the PID requirement for the endcap region of the STCF. The conceptual design of the DTOF detector and its geometry optimization is herein presented. The PID performance of the detector is studied using Geant4 simulation. With a proper reconstruction algorithm, an overall time resolution of ~50 ps is achieved for the detector with an optimum geometry when convoluting contributions from all other sources, including the transit time spread (TTS) of the photodetector, electronic timing accuracy, and an assumed precision (~40 ps) of the event start time. A $π$/K separation power of better than 4$σ$ at the momentum of 2 GeV/c is achieved over the entire sensitive area of the DTOF detector, thereby fulfilling the physics requirement of the PID detector for the experiment at the STCF.

physics.ins-det